Search found 67 matches

by dvid9976
09 Oct 2018 09:25
Forum: Voicemail (46x5)
Topic: 4645 transfer to Pilot voice guide
Replies: 2
Views: 223

Re: 4645 transfer to Pilot voice guide

you are totally right mate, thx TGN.
did not realize of that option which is called Transfer redirection in the Oxe, instead of "Transfer to pilot in dissuasion" as doc says.

I was totally mistaken looking for a parameter to change into 4645, Connection COS, bla, bla, bla...

thank you sir!!
by dvid9976
08 Oct 2018 16:44
Forum: Voicemail (46x5)
Topic: 4645 transfer to Pilot voice guide
Replies: 2
Views: 223

4645 transfer to Pilot voice guide

hello there I just configured a 4645 Att.Attendant beforte a pilot in order to provide the caller a couple of options before reaching the CCD. The thing works fine until the pilot gets into GF state, when it is connected to a "out of hours" voice guide. when the pilot is in GF and I pick the option ...
by dvid9976
26 Mar 2018 16:19
Forum: PWT/DECT System
Topic: High density of users in one site
Replies: 9
Views: 1872

Re: High density of users in one site

15 per floor?
That is 45 RBS in a 3 floors building 105m long / 45m wide.

As I said, I have some experience in less populated DECT enviroments, but nothing as big.

thank you


David.
by dvid9976
16 Mar 2018 06:17
Forum: PWT/DECT System
Topic: High density of users in one site
Replies: 9
Views: 1872

Re: High density of users in one site

Thank you guys
by dvid9976
15 Mar 2018 07:50
Forum: PWT/DECT System
Topic: High density of users in one site
Replies: 9
Views: 1872

Re: High density of users in one site

hello there!

Thank you for your comments; I'm afraid that I did not mention that it is OXE what we are talking about :-(

best regards

DA
by dvid9976
14 Mar 2018 06:02
Forum: PWT/DECT System
Topic: High density of users in one site
Replies: 9
Views: 1872

High density of users in one site

hello there guys, do you have any experiencie on high user density dect installations? I mean, sites where many base stations are requiered not for coverage purposes but for a high number of users? my customer wants to move almost all their users from analog sets to dect; I performed a Dect S.S and ...
by dvid9976
10 Jul 2017 04:46
Forum: Application
Topic: 4645 Transfer to multiline Set
Replies: 8
Views: 1105

Re: 4645 Transfer to multiline Set

Hello guys

It looks like the problem was due to the multiline "thing" not working properly and got solved after a reboot of the PCX.

Thank you for your suggestions and time

Best regards

DA
by dvid9976
10 Jul 2017 03:58
Forum: Classes of Services
Topic: Multi Line on DDI
Replies: 21
Views: 4423

Re: Multi Line on DDI

Hello guys, sorry for the late reply. @ Vad you were right T3 traces showed Disconnect/Busy. It is a OXE R7.0-f4.401-13 We got the customer to authorize a maintenance window and restarted the OXE last weekend. I'm a bit frustrated to say that after de reboot the problem was solved and now all multil...
by dvid9976
03 Jul 2017 18:01
Forum: Classes of Services
Topic: Multi Line on DDI
Replies: 21
Views: 4423

Re: Multi Line on DDI

Attached the readkey output

Thank you
by dvid9976
03 Jul 2017 12:52
Forum: Classes of Services
Topic: Multi Line on DDI
Replies: 21
Views: 4423

Re: Multi Line on DDI

It is an E1 Isdn 30 channels; I checked it was not congested at time that I tested