Search found 19 matches

by Man
04 Mar 2010 06:55
Forum: Application
Topic: How to bar incoming External call CDR string coming from OXE crystal
Replies: 2
Views: 1546

Thanks murraya
Will try the configuration
-man
by Man
04 Mar 2010 02:40
Forum: Application
Topic: How to bar incoming External call CDR string coming from OXE crystal
Replies: 2
Views: 1546

How to bar incoming External call CDR string coming from OXE crystal

Hi Readers, can any one knows How to bar incoming call CDR string coming from OXE crystal. PMS vender dont want incoming external calls string.OXE is sending cdr string for incoming external call also.Is there any configuration in OXE for this?.... Also would like to know how can I restrict intercom...
by Man
02 Mar 2010 01:20
Forum: Classes of Services
Topic: PIN configuration
Replies: 5
Views: 4059

Hi Sera
thanks for reply
I will try this cfgupdate.........

Regards,
Man
by Man
26 Feb 2010 03:46
Forum: Users
Topic: ring after any activity on ANALOG set with CLIP activated
Replies: 8
Views: 9084

Yeah
I have tried this and it works.....
by Man
26 Feb 2010 01:33
Forum: Classes of Services
Topic: PIN configuration
Replies: 5
Views: 4059

Thanx for reply I already tried Private calls profile configuration. But in this there is dependency on personal trunk group prefexes and I have to create 3 different prefix for local STD and ISD. the external calls cant be controlled by PINs, as well it can be controlled by personal trunk prefexes....
by Man
24 Feb 2010 04:01
Forum: Classes of Services
Topic: PIN configuration
Replies: 5
Views: 4059

PIN configuration

Hi, I am having requirement such as i have to creatte 30 PIN which can dial only local, 30 PIN which can dial local and STD and 30 PIN can dial Local, STD and ISD calls. All PIN should work from any of extensions of my system. How it could be configured. can any one give me a configuration info........
by Man
24 Feb 2010 03:49
Forum: Application
Topic: Billing port hanging problem on TCP/IP in common HW
Replies: 1
Views: 1211

Billing port hanging problem on TCP/IP in common HW

Hello readers, I am having R8-Hotel configuration in which billng is on TCP IP and is interfaced with third party PMS name as company IDS. At the time of huge Guest check In PMS is hanging. i have attached the incvisu logs for reference can any one help me regarding if problem is from our system sid...
by Man
27 Nov 2009 05:31
Forum: Beginner's questions about the Common Hardware
Topic: 0:2663=IPC Chorus err: appli LINF oper 6 err -11-OXE Common
Replies: 1
Views: 2212

0:2663=IPC Chorus err: appli LINF oper 6 err -11-OXE Common

Hi I am getting below logs frequently in incvisu on my OXE common Rls 8 DD/MM/YY 09:26:19 000001M|---/--/-/---|=0:2663=IPC Chorus err: appli LINF oper 6 err -11 DD/MM/YY 09:26:37 000001M|---/--/-/---|=2:2092=IPC:Th[7246-linf] -> Ac[7241-#linf] Prt a0000.d700 5 255 can anyone help me what could be th...
by Man
03 Nov 2009 03:08
Forum: Beginner's questions about the OmniPCX OFFICE
Topic: V24 serial Billing Port with 4035 Attendent in OXO
Replies: 0
Views: 876

V24 serial Billing Port with 4035 Attendent in OXO

Hi friends, Can anyone give me the following details. Currently my OXO R.6 is working on IP metering in Hotel Liscence configuration. But it is not stable, Check In Check out is not working properely.I have to restart OHL driver several times. I heared Serial port metering is stable thats why if I w...
by Man
27 Jul 2009 05:47
Forum: Beginner's questions about the Crystal Hardware
Topic: name display problem on 4019 and 4029 digital sets
Replies: 5
Views: 7582

Re: name display problem on 4019 and 4029 digital sets

Hi, I have changed the parameter in Phone facility categories Virtual set on CMP board = 0( default 0).... and found its working... Names are displaying on digital sets Also I have checked the following setting System--> Consult Modify---> Display call name on calling set- true. Any way thanks for y...

Go to advanced search