Search found 55 matches

by manoj
05 Sep 2022 06:23
Forum: MAIN
Topic: "Bad gateway and Destination out of order" logs getting while incoming call from Public SIP trunk
Replies: 1
Views: 979

"Bad gateway and Destination out of order" logs getting while incoming call from Public SIP trunk

Hi, In our OXO system we have configured public SIP trunk with ISP. Outgoing calls are working fine. while calling incoming we are getting "Bad gateway and Destination out of order" logs on the call traces. ISP has confirmed that they are sending 8 digits to us. I have mapped the Main SIP ...
by manoj
24 Jan 2022 01:15
Forum: OXE (Crystal / Common) - System Documentation
Topic: Serial port not functioning on IBMX3250-M6
Replies: 2
Views: 1556

Re: Serial port not functioning on IBMX3250-M6

Hi, Yes, I check the serial port COM1 configuration in BIOS settings. Port is enabled. baud rate: 9600 parity none: data bits (word size): 8 stop bits: 1 flow control: none Once the server will boot it shows on the display "GRUB loading stage2. Output on the serial line". But no output get...
by manoj
18 Jan 2022 06:18
Forum: OXE (Crystal / Common) - System Documentation
Topic: Serial port not functioning on IBMX3250-M6
Replies: 2
Views: 1556

Serial port not functioning on IBMX3250-M6

Hi,

I got a preinstalled Release 12.1 appliance server IBMX3250-M6 from Alcatel.

But the server is not giving any output on the serial port so I cant manage the IP details on the netadmin.

Please advise.
by manoj
20 Dec 2017 04:53
Forum: OmniTouch 8450 Fax Software
Topic: FAX User login error
Replies: 1
Views: 3919

FAX User login error

Hi, I have an OTBE server with OFS 7.0. It was working fine, suddenly I got error while login fax user (screen shot attached). when I login to the OTBE I have found the disk space issue. I removed unwanted files and make around 20 GB free. after that I have restarted Tomcat,xmservices. but I am gett...
by manoj
25 Oct 2017 03:14
Forum: MAIN
Topic: Public SIP trunk on OXO 10.2
Replies: 4
Views: 3163

Public SIP trunk on OXO 10.2

Hi, I am trying to configure a Public SIP trunk on OXO 10.2 release. The service provider has given outbound proxy,port, installation number, DID and domain name. I have configured the VOIP trunk and create ARS Trunk group, ARS prefix, Gateway parameters and SIP account but in the history table it s...
by manoj
23 Aug 2017 04:54
Forum: OmniVista 8770
Topic: OmniVista 8770 R3.0 error to add Sip device
Replies: 5
Views: 4242

Re: OmniVista 8770 R3.0 error to add Sip device

Thanks...Its working now...
by manoj
22 Aug 2017 03:23
Forum: OmniVista 8770
Topic: OmniVista 8770 R3.0 error to add Sip device
Replies: 5
Views: 4242

Re: OmniVista 8770 R3.0 error to add Sip device

Hi,

Apache is showing error. attached the image.

hope port 80 is used by another application.
by manoj
21 Aug 2017 08:18
Forum: OmniVista 8770
Topic: OmniVista 8770 R3.0 error to add Sip device
Replies: 5
Views: 4242

OmniVista 8770 R3.0 error to add Sip device

Hi, I have installed 8770 R.30 with my OXE 11.2. synchronization is working fine. I want to configure 8088 handset with my OXE. So in USER tab on 8770 when I am associating a SIP device with user 8770 is giving below error. "Retrieve user entries 'Uid=123 Test,o=FIT,o=directoryRoot' error: Conn...
by manoj
20 Aug 2017 05:58
Forum: Rainbow
Topic: Rainbow with OXO Connect
Replies: 2
Views: 5434

Re: Rainbow with OXO Connect

The issue got resolved.....the issue was with the PBX ID provide by Rainbow

Thanks
by manoj
13 Aug 2017 05:58
Forum: Rainbow
Topic: Rainbow with OXO Connect
Replies: 2
Views: 5434

Rainbow with OXO Connect

Hi All,

I am trying to do a Rainbow setup with My OXO Connect System.

I have got the Activation code from Rainbow admin.

But when I am synchronize with the OXO connect, system shows disconnected.

Anyone can help..