Search found 430 matches
- 22 May 2021 05:27
- Forum: SIP
- Topic: SIP user did not connect to the redundant CPU went it is in main role.
- Replies: 31
- Views: 8187
Re: SIP user did not connect to the redundant CPU went it is in main role.
Instead of trying with IP address, try to configure CPU NAME ( FQDN ) and seem failover will work. I remember I did it for some sites.
- 21 Apr 2021 06:54
- Forum: JOBS
- Topic: Alcatel OXE French Speaker
- Replies: 1
- Views: 3290
Re: Alcatel OXE French Speaker
Hi, I have been working on Alcatel 4200, 4400, OXE, OXO, & OTCC products, familiar with VOIP, SIP, ABC-F, CCD system, large enterprise networks and handling various project & implementation as well techno commercial activities. Alcatel Lucent internal Voice network in APAC, EMEA & AMS wa...
- 21 Apr 2019 01:44
- Forum: JOBS
- Topic: OXO Connect/Evolution ACFE/ACSE in Canada
- Replies: 2
- Views: 4691
Re: OXO Connect/Evolution ACFE/ACSE in Canada
I have come to know through website, there is a vacancy in your esteemed organization. I am presently working as a ICT Consultant ( Free Lancer )for APAC & EMEA region. I have been working on Alcatel OXE, OXO, 4400 & OTCC products and handling various project & implementation as well tec...
- 21 Apr 2019 01:42
- Forum: JOBS
- Topic: Good job offer in Leipzig-Germany / Gutes Jobangebot in Leipzig-Deutschland -- Alcatel TK system administrator
- Replies: 1
- Views: 3386
Re: Good job offer in Leipzig-Germany / Gutes Jobangebot in Leipzig-Deutschland -- Alcatel TK system administrator
Hi, I have come to know through website, there is a vacancy in your esteemed organization. I am presently working as a ICT Consultant ( Free Lancer )for APAC & EMEA region. I have been working on Alcatel OXE, OXO, 4400 & OTCC products and handling various project & implementation as well...
- 11 Jul 2014 08:39
- Forum: CCD / CCS / CCIVR
- Topic: ACR - Realtime Skill can be seen for logged in Agents
- Replies: 0
- Views: 1802
ACR - Realtime Skill can be seen for logged in Agents
Hi All, I have a 9 different skills, Agents are assigned and script is working ok. When supervisor want to verify the logged in Agents are covered by all skills or not in real time window PG, we can't able to see the skills for Agents who are logged in stat, is it possible. I tried via window -> Cus...
- 29 Jul 2012 23:55
- Forum: MAIN
- Topic: Ananlog trunk lines are going O/S automatic
- Replies: 7
- Views: 3818
Re: Ananlog trunk lines are going O/S automatic
Hi Mohamed, I resolved this issue, my case was like after upgrade OXE, compare to system binary NDDI binary was not matching, there is command to cross check this binary versions, there is no way forcing NDDI to download new binary because when NDDI boots automatically it download the binaries from ...
- 10 Jul 2012 07:52
- Forum: H323 / Sip
- Topic: OXE H323 O/G issue via ISDN
- Replies: 9
- Views: 5926
Re: OXE H323 O/G issue via ISDN
Hi Alex,
Issue is solved, problem in RBT for toll free numbers, so we have enabled No RBT for H323 calls = true then it started working. thanx for your support and reply man..
regards,
Pandian.
Issue is solved, problem in RBT for toll free numbers, so we have enabled No RBT for H323 calls = true then it started working. thanx for your support and reply man..
regards,
Pandian.
- 10 Jul 2012 02:41
- Forum: H323 / Sip
- Topic: OXE H323 O/G issue via ISDN
- Replies: 9
- Views: 5926
Re: OXE H323 O/G issue via ISDN
Hi Alex,
I did a mtracer for H323 i noticed this error below, any idea about this..
) Test_Compatibility_for_transit type1 0x63 type2 0x43 : incompatible
attached trace for your reference in case..
I did a mtracer for H323 i noticed this error below, any idea about this..
) Test_Compatibility_for_transit type1 0x63 type2 0x43 : incompatible
attached trace for your reference in case..
- 09 Jul 2012 05:56
- Forum: H323 / Sip
- Topic: OXE H323 O/G issue via ISDN
- Replies: 9
- Views: 5926
Re: OXE H323 O/G issue via ISDN
Hi Alex,
Thanx for your reply, Am stuck in one place how come one number is working other number not, if H323 problem it should come on both numbers correct. what could be the possible reason for this, any idea.
Thanx for your reply, Am stuck in one place how come one number is working other number not, if H323 problem it should come on both numbers correct. what could be the possible reason for this, any idea.
- 06 Jul 2012 11:58
- Forum: H323 / Sip
- Topic: OXE H323 O/G issue via ISDN
- Replies: 9
- Views: 5926
Re: OXE H323 O/G issue via ISDN
Hi Alex, Thanks for your reply, i have 4 ISDN in one trunk group total 120 channels. ofcourse i tried removing all other channels kept one by one cards still issue is same. I felt strange about this issue, never faced this kind of issue man both are same 6 series number starting with but one is work...