- 18 Nov 2019 22:56
- Forum: ON SITE TROUBLES
- Topic: Call Features Problem
- Replies: 2
- Views: 6731
Call Features Problem
Dear , I migrated from R5 to R12.1 one year ago, it worked normally till 5 days ago. The system was halted shutdown because of the electric breakdown. After rebooting, the system was still working, but some call features were not. Example: call forward, cancel forward, call pickup, room status... Fo...
- 26 Sep 2019 05:46
- Forum: SIP
- Topic: Transit SIP Trunk
- Replies: 2
- Views: 2595
Re: Transit SIP Trunk
I dit it. Configure ARS prefix as enbloc then it worked.
- 14 Sep 2019 00:39
- Forum: SIP
- Topic: Transit SIP Trunk
- Replies: 2
- Views: 2595
Transit SIP Trunk
Hi all, I have 2PBX OXE R11.2 connected via SIP TRUNK, ABC-F / SIP. Ext from Site A can call to Ext Site B and vice versa. Now site A has ISDN trunk to PSTN, I want Ext site B transit to site A via SIP TRUNK to make a outgoing call. At site B, I create 9 for ARS prefix, call number 09xx in Discrimin...
- 12 Sep 2019 06:01
- Forum: Application
- Topic: Message Waiting Lamp Not Work
- Replies: 8
- Views: 5389
Re: Message Waiting Lamp Not Work
It worked right now. Follow Doc R12, MWI control, SLI16-2
- 04 Sep 2019 05:28
- Forum: Application
- Topic: Message Waiting Lamp Not Work
- Replies: 8
- Views: 5389
Re: Message Waiting Lamp Not Work
Swap pair, not work Try to Cetic phone, not work In Board slot, I tried to set "Send Init Dynamic Msg" to TRUE and "Para by default" to FALSE. Then go to "Go Down" , Dynamic Init Parameter, I set P0 P1 P2 P3 is 3 2 255 255, follow as Alcatel Document message led for SLI...
- 02 Sep 2019 07:02
- Forum: Application
- Topic: Message Waiting Lamp Not Work
- Replies: 8
- Views: 5389
Re: Message Waiting Lamp Not Work
Could you please tell me details of the polarity?
- 02 Sep 2019 03:40
- Forum: Application
- Topic: Message Waiting Lamp Not Work
- Replies: 8
- Views: 5389
Re: Message Waiting Lamp Not Work
Yes, I did it first. In User I set Message LED : TRUE
- 01 Sep 2019 07:55
- Forum: Application
- Topic: Message Waiting Lamp Not Work
- Replies: 8
- Views: 5389
Message Waiting Lamp Not Work
Hi, I have a oxe R11.2, use analog phone branch "COTEL" FG1088A as Guest deskphone. I configure *56 for Message deposit and #56 for Switch Message led OFF. From a digital phone, I press *56 + guest number, I see the "message left" notification (it mean ok). When pickup the guest ...
- 17 Jun 2019 04:51
- Forum: Translator
- Topic: Block an incoming call from particular DID
- Replies: 39
- Views: 52485
Re: Block an incoming call from particular DID
Dear Vad, I continue 1/ Incoming DID (3910 1234) - ext (1098) 2/ Translator / called filtered number 1098, entity 20, public rerouting: false 3/ And then, teleservice filtering 1098 (ISDN service is other), index 1, overflow to 7308 (this real ext for testing) 4.1/ Create Abbreviated Numbering (mean...
- 06 Jun 2019 03:26
- Forum: Translator
- Topic: Block an incoming call from particular DID
- Replies: 39
- Views: 52485
Re: Block an incoming call from particular DID
Usually you have Direct SD - in management declared f.e. index of 1st SD = 0, numbers of SD = 1000. For SD by range (before SD creation) - you need to manage "range". f.e. for Range 0 - declare - index of 1st SD=1000 and numbers of SD=100. After this - you can create SD in range 0. In ano...