Search found 13 matches
- 18 Feb 2019 01:52
- Forum: OmniVista 8770
- Topic: OV8770 error "cannot initialize scheduler API"
- Replies: 2
- Views: 2774
OV8770 error "cannot initialize scheduler API"
Hi, After installation of OV8770 (R2.0.09.03) on Windows Server 2012 R2 Standard, it is observed that scheduler is not started up correctly and it opens with a blank status e.g. cannot see daily job, weekly job or RTU etc under scheduler.The OXE node is created correctly but not able to synchronize ...
- 22 Nov 2017 02:58
- Forum: SIP
- Topic: Does any Alcatel-Lucnet SIP phone work with open 3rd party SIP server
- Replies: 1
- Views: 1826
Does any Alcatel-Lucnet SIP phone work with open 3rd party SIP server
Hi ,
I would like to know which Alcatel-Lucent SIP phone works with any other 3rd party SIP Server (e.g. Avaya, Asterisk etc.)
Have anybody tested it, if yes then which Alcatel-Lucent SIP phone (model number) and with which 3rd party server?
Please reply
Regards
I would like to know which Alcatel-Lucent SIP phone works with any other 3rd party SIP Server (e.g. Avaya, Asterisk etc.)
Have anybody tested it, if yes then which Alcatel-Lucent SIP phone (model number) and with which 3rd party server?
Please reply
Regards
- 22 Mar 2017 06:08
- Forum: OmniSwitch 6250
- Topic: OS6250-24 console port not working
- Replies: 6
- Views: 14084
Re: OS6250-24 console port not working
Hi,
I have tested and verified console cable. It is working fine with other Alcatel-Lucent OmniStack LS6224P.
I have also tested with all speed and flow setting but no progress.
Could you please provide Break Key Sequence combination of OS6250-24? So that I may further test it
I have tested and verified console cable. It is working fine with other Alcatel-Lucent OmniStack LS6224P.
I have also tested with all speed and flow setting but no progress.
Could you please provide Break Key Sequence combination of OS6250-24? So that I may further test it
- 17 Mar 2017 02:22
- Forum: OmniSwitch 6250
- Topic: OS6250-24 console port not working
- Replies: 6
- Views: 14084
Re: OS6250-24 console port not working
Can I have pin configuration of console cable (RJ-45 to DB-9 female end) to verify my cable, please?
- 17 Mar 2017 01:44
- Forum: Beginner's questions about the Crystal Hardware
- Topic: How to upgrade OXE R6.2 (CPU6) to R11.2(CPU7-2)
- Replies: 4
- Views: 4010
Re: How to upgrade OXE R6.2 (CPU6) to R11.2(CPU7-2)
Further to add that I have new OPS (R11.2) for the migration, as well
- 17 Mar 2017 01:40
- Forum: Beginner's questions about the Crystal Hardware
- Topic: How to upgrade OXE R6.2 (CPU6) to R11.2(CPU7-2)
- Replies: 4
- Views: 4010
Re: How to upgrade OXE R6.2 (CPU6) to R11.2(CPU7-2)
Well, I have downloaded OXE R11.2.2 from BPWS and I have experienced of OXE SW installation.
Please guide me about procedure for OXE SW Release migration, step by step.
Regards
Please guide me about procedure for OXE SW Release migration, step by step.
Regards
- 16 Mar 2017 07:32
- Forum: Beginner's questions about the Crystal Hardware
- Topic: How to upgrade OXE R6.2 (CPU6) to R11.2(CPU7-2)
- Replies: 4
- Views: 4010
How to upgrade OXE R6.2 (CPU6) to R11.2(CPU7-2)
Hi,
I need procedure for OXE software Release up-gradation from R6.2 to R11.2. The existing hardware is CPU6 and this CPU6 has to be replaced with CPU7-2 during the up-gradation. A new GPA2 board will also be added in OXE as per OPS file received to me.
Regards
Rizwan
I need procedure for OXE software Release up-gradation from R6.2 to R11.2. The existing hardware is CPU6 and this CPU6 has to be replaced with CPU7-2 during the up-gradation. A new GPA2 board will also be added in OXE as per OPS file received to me.
Regards
Rizwan
- 16 Mar 2017 07:08
- Forum: OmniSwitch 6250
- Topic: OS6250-24 console port not working
- Replies: 6
- Views: 14084
OS6250-24 console port not working
Hi,
How to check and verify console port of OS6250-24
Please advise
Regards
How to check and verify console port of OS6250-24
Please advise
Regards
- 22 Feb 2017 16:45
- Forum: Trunk Groups
- Topic: E&M (MFC-R2)
- Replies: 1
- Views: 1814
E&M (MFC-R2)
Hi,
I have to interface OXE R11.0 with other PABX (DCX-600) through EMTL board (4W, MFC-R2).
I want to know which type of trunk group to be created for this and which trunk COS to be assigned to allocated trunk.
Please suggest
Regards
I have to interface OXE R11.0 with other PABX (DCX-600) through EMTL board (4W, MFC-R2).
I want to know which type of trunk group to be created for this and which trunk COS to be assigned to allocated trunk.
Please suggest
Regards
- 21 Feb 2017 16:59
- Forum: Trunk Groups
- Topic: E&M Type5
- Replies: 10
- Views: 7584
Re: E&M Type5
Hi
Is the issue resolved?
Is the issue resolved?