Re: Name not display
Hi all I am just curious about this. mdhussainvlr, let me see if I understand your case. When you call from an extension of OXE to a SIP extension (Avaya set registered on OXE), Avaya set does not show the name of who is calling, right? If I understood right, I ran a test with a lab system I have wi...
- 07 Feb 2018 14:51
- Forum: H323 / IP / Pimphony
- Topic: Incoming calls from mobile phones through a public SIP Trunk to an OXO Connect R2.1 are rejected
- Replies: 8
- Views: 6031
Re: Incoming calls from mobile phones through a public SIP Trunk to an OXO Connect R2.1 are rejected
Hi aurelian
Have you ever tried to enable the check-box P-Access-Network-Info in Gateway Parameters --> your SIP gateway --> Identity?
I have been looking for an information during a test here and seen this option.
Best regards.
Have you ever tried to enable the check-box P-Access-Network-Info in Gateway Parameters --> your SIP gateway --> Identity?
I have been looking for an information during a test here and seen this option.
Best regards.
- 05 Feb 2018 13:04
- Forum: H323 / IP / Pimphony
- Topic: Incoming calls from mobile phones through a public SIP Trunk to an OXO Connect R2.1 are rejected
- Replies: 8
- Views: 6031
Re: Incoming calls from mobile phones through a public SIP Trunk to an OXO Connect R2.1 are rejected
Hi aurelian As giovanni.attolini wrote, it is necessary to check if OXO is compliant with RFC3455. Looking for OXO datasheet, it does not mention that RFC: Trunk standards compliance RFC 3261, RFC 3261, RFC 3262, RFC 3264, RFC 2327, RFC 2833, RFC 2822, RFC 3515, RFC 360, RFC 3966, RFC 3398, RFC 3323...
- 02 Feb 2018 10:57
- Forum: SIP
- Topic: INVITE field "to" with letters
- Replies: 3
- Views: 2669
Re: INVITE field "to" with letters
Hi cavagnaro
I think the same. First time I see an INVITE this way. Usually it is just numbers. But it is just a test, and there is no a need to run immediately, I can play with that.
Best regards.
I think the same. First time I see an INVITE this way. Usually it is just numbers. But it is just a test, and there is no a need to run immediately, I can play with that.
Best regards.
- 02 Feb 2018 07:26
- Forum: SIP
- Topic: INVITE field "to" with letters
- Replies: 3
- Views: 2669
INVITE field "to" with letters
Hello I am running some tests with a SIP provider. System is OXE R11.0.1-k1.520-42-br-c0s1. I configured SIP External Gateway and OXE is registering and making calls properly. My situation is with the incoming calls, OXE is replying 404 not found. I know the reason, or at least I think I know. The n...
- 17 Jan 2018 05:16
- Forum: Networking
- Topic: Gateway Status Alive is Down
- Replies: 3
- Views: 5175
Re: Gateway Status Alive is Down
Hi I understand from your remarks it is still with networking problem. It is not the OXO, in my opinion. Every 6-8 Minutes the Remote gateway goes up and down event 223 and 224 This is check out by ping. In gateway parameters or ARS Prefixes you have ICMP configuration (300 ms) that checks up/down o...
- 15 Jan 2018 11:22
- Forum: Networking
- Topic: Gateway Status Alive is Down
- Replies: 3
- Views: 5175
Re: Gateway Status Alive is Down
Hi md28 You wrote the answer: The ping to the IP address and traceroute to the IP addres to our SIP provider using CMD is fine however trace route using services/webapps could not arrive to the SIP provider end. It is a networking problem. If you can reach SIP provider IP address using CMD from a co...
- 14 Dec 2017 12:08
- Forum: Beginner's questions about the OmniPCX OFFICE
- Topic: OXO CLIP issue in APA8 Board
- Replies: 3
- Views: 2473
Re: OXO CLIP issue in APA8 Board
Hi
Best regards.
Listen to the FSK signal in both calls. Try to check out if the FSK signal is sent differently from Siemens.I found the ring cadence is different in intercom and external calls in the Seimens PBX analog lines.
Best regards.
- 07 Dec 2017 12:08
- Forum: H323 / IP / Pimphony
- Topic: OXO RE-INVITE with Authentication
- Replies: 10
- Views: 16950
Re: OXO RE-INVITE with Authentication
Hi Clever I am facing the same situation here. Did you change any configuration in OXO to send Re-INVITE after 407? You posted two traces where I can see OXO just sends an ACK after 407 and nothing more. But the last trace you posted, after ALE support, I can see OXO is sendind Re-INVITE. Best regar...
- 21 Nov 2017 05:01
- Forum: Beginner's questions about the OmniPCX OFFICE
- Topic: Incoming calls to oxo extensions through apa card not ringing
- Replies: 3
- Views: 2560
Re: Incoming calls to oxo extensions through apa card not ringing
Hi
Does it ring in any extension of attendant group?
Is the number of call distribution configured in Public Numbering Plan?
Best regards.
Does it ring in any extension of attendant group?
Is the number of call distribution configured in Public Numbering Plan?
Best regards.