OXE CPU switch-over

Post Reply
gilcsr
Member
Posts: 2
Joined: 11 Jul 2018 10:28

OXE CPU switch-over

Post by gilcsr »

Hello
just a question...
is it normal that during a cpu switch-over (bascul main xa to xb) all the DECT communications are lost ?
only the IP or Analogic communications are maintained
the redundancy is ok
sorry for my english...
thanks for your answers

oxe R10.1.1-j2.603-29-b-fr-c0
User avatar
mustafa.ahmad
Member
Posts: 253
Joined: 27 May 2010 03:23

Re: OXE CPU switch-over

Post by mustafa.ahmad »

No, it is not normal, all the communications must be as they are, only the calls that are being placed or in routing mode get disconnected. Calls already established must remain as in their state before bascul.

Maybe there is bug in the patch.
vad
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 3806
Joined: 23 Sep 2004 06:47

Re: OXE CPU switch-over

Post by vad »

I think - your DECT sinchronized from CPU. And in this case during switch-over - DECT network reinitalized and all communication lost (the same problem can be with ABC-F calls)
gilcsr
Member
Posts: 2
Joined: 11 Jul 2018 10:28

Re: OXE CPU switch-over

Post by gilcsr »

hi
thanks for your answers :)
so, my ibs or DECT can be synchronized whith only one CPU and that's why it can't be in redondancy ?
nothing to do?
User avatar
Eliott
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 640
Joined: 10 Feb 2010 03:43

Re: OXE CPU switch-over

Post by Eliott »

You need two DECT8_SYNC boards to have a seamless clock.
User avatar
Eliott
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 640
Joined: 10 Feb 2010 03:43

Re: OXE CPU switch-over

Post by Eliott »

What are the components?
Can you post a config all and infocs?
Post Reply