Wondering if someone can help me diagnose an issue. we have a 6800 which has 2 static default gateways. One with metric 1 and the other with metric 15. We know both gateways work as if we manually set a PC to use either of the two it works and breaks out to WAN.
Anyways we removed the lower cost metric which was metric 1 and it stopped routing to WAN even though there was another default gateway present with metric 15.
see errors below, It is a strange one as we did the exact same thing at another site and it worked perfectly. As you can see at the bottom of the log it shows we added the metric 1 route back in which fixed issue but does not explain why what I did would not work?
The two default GW are as follows:
ip static-route 0.0.0.0/0 gateway 10.1.0.224 metric 1 (This is the one we removed)
ip static-route 0.0.0.0/0 gateway 10.1.0.231 metric 15
Code: Select all
May 12 12:59:30 "Switch Name" swlogd: SES CMD alarm(1) CLI log, user: admin (10.1.12.65), cmd: no ip static-route 0.0.0.0/0 gateway 10.1.0.224 metric 1, result: SUCCESS
May 12 12:59:42 "Switch Name" swlogd: ChassisSupervisor SharedMem Sync info(5) SMSyncUpdateCMMVer1: 2/0 oper status change from 4 to 0
May 12 12:59:52 "Switch Name" swlogd: ChassisSupervisor SharedMem Sync info(5) SMSyncUpdateCMMVer1: 2/0 oper status change from 4 to 0
May 12 13:00:12 "Switch Name" swlogd: ChassisSupervisor SharedMem Sync info(5) SMSyncUpdateCMMVer1: 2/0 oper status change from 4 to 0
May 12 13:00:20 "Switch Name" swlogd: vcmCmm ipc info(5) CMM:vcmCMM_server_rx@1358: Process (protOperData, len 96, src 0/65/33381)
May 12 13:00:20 "Switch Name" swlogd: vcmCmm ipc info(5) CMM:vcmCMN_tx_data_cb@3076: distribChassisStatus2NI -> (chassis 0, Slot 1, port 17653, len 96)
May 12 13:00:20 "Switch Name" swlogd: vcmNi ipc info(5) NI:vcmNI_peer_cmm_ni_rx@836: Process msg (distribChassisStatus2NI, len 96, src 0/65)
May 12 13:00:22 "Switch Name" swlogd: ChassisSupervisor SharedMem Sync info(5) SMSyncUpdateCMMVer1: 2/0 oper status change from 4 to 0
May 12 13:00:42 "Switch Name" swlogd: ChassisSupervisor SharedMem Sync info(5) SMSyncUpdateCMMVer1: 2/0 oper status change from 4 to 0
May 12 13:00:52 "Switch Name" swlogd: ChassisSupervisor SharedMem Sync info(5) SMSyncUpdateCMMVer1: 2/0 oper status change from 4 to 0
May 12 13:01:06 "Switch Name" swlogd: MIP_GATEWAY mipgwd alert(3) ---- Logging MIP_SET type, command to be sent:
May 12 13:01:06 "Switch Name" swlogd: MIP_GATEWAY mipgwd alert(3) MIP_SET(4) msg_id(145031192) (APPID_CLI(67/0) -> APPID_DRC_IPRM_VRF(125)) values:
May 12 13:01:06 "Switch Name" swlogd: MIP_GATEWAY mipgwd alert(3) Table(75804/0): alaIprmStaticRouteTable
May 12 13:01:06 "Switch Name" swlogd: MIP_GATEWAY mipgwd alert(3) Index: 0 0 0 0 0 0 0 0 10 1 0 224
May 12 13:01:06 "Switch Name" swlogd: MIP_GATEWAY mipgwd alert(3) Object(4) Name: alaIprmStaticRouteMetric
May 12 13:01:06 "Switch Name" swlogd: MIP_GATEWAY mipgwd alert(3) Object Value(uint32): 1
May 12 13:01:06 "Switch Name" swlogd: MIP_GATEWAY mipgwd alert(3) Object(7) Name: alaIprmStaticRouteType
May 12 13:01:06 "Switch Name" swlogd: MIP_GATEWAY mipgwd alert(3) Object Value(uint32): 1
May 12 13:01:06 "Switch Name" swlogd: MIP_GATEWAY mipgwd alert(3) Object(5) Name: alaIprmStaticRouteStatus
May 12 13:01:06 "Switch Name" swlogd: MIP_GATEWAY mipgwd alert(3) Object Value(uint32): 4
May 12 13:01:06 "Switch Name" swlogd: MIP_GATEWAY mipgwd alert(3) ----------------
May 12 13:01:06 "Switch Name" swlogd: SES CMD alarm(1) CLI log, user: admin (10.1.12.65), cmd: ip static-route 0.0.0.0/0 gateway 10.1.0.224 metric 1, result: SUCCESS