Post by pinnback » 27 Nov 2019 08:04

Hi,

i have a VC of two 6860E and the logfile is full with:
2019 Nov 27 01:41:02.774 mgmtsw-101 swlogd vcmCmm config INFO: CMM:vcmCMN_activity_timer_handler_cb@19408: Handled tx del auto vfl:14/1053/1
2019 Nov 27 01:41:02.775 mgmtsw-101 swlogd vcmCmm auto_vfl INFO: CMM:vcmCMN_activity_timer_handler_cb@19787: Re-tx auto vfl port 1/1/53: autoVfl del (chas 1 slot 65)
2019 Nov 27 01:41:02.775 mgmtsw-101 swlogd vcmCmm config INFO: CMM:vcmCMM_send_auto_vfl_enable_msg_2peercmm@11726: autoVflEnablePeerCMM msg (0x9901e4, dst 1/65 ret 0)
2019 Nov 27 01:41:02.775 mgmtsw-101 swlogd vcmCmm config INFO: CMM:vcmCMN_activity_timer_handler_cb@19408: Handled tx del auto vfl:14/1054/1
2019 Nov 27 01:41:02.775 mgmtsw-101 swlogd vcmCmm auto_vfl INFO: CMM:vcmCMN_activity_timer_handler_cb@19787: Re-tx auto vfl port 1/1/54: autoVfl del (chas 1 slot 65)
.....

I also think the auto-VC thingy didn't work. I have automatically generated LinkAgg's that have no use at the moment. They do not have physikal Ports assigned and are operational down.

write term
. . .
linkagg lacp agg 123 size 16 hash tunnel-protocol admin-state enable
linkagg lacp agg 123 name "Created by Auto-Fabric on Fri Feb 21 02:20:52 2014"
linkagg lacp agg 123 actor admin-key 65531
linkagg lacp agg 124 size 16 hash tunnel-protocol admin-state enable
linkagg lacp agg 124 name "Created by Auto-Fabric on Fri Feb 21 02:19:27 2014"
linkagg lacp agg 124 actor admin-key 65532
linkagg lacp agg 125 size 16 hash tunnel-protocol admin-state enable
linkagg lacp agg 125 name "Created by Auto-Fabric on Fri Feb 21 01:55:06 2014"
linkagg lacp agg 125 actor admin-key 65533
linkagg lacp agg 126 size 16 hash tunnel-protocol admin-state enable
linkagg lacp agg 126 name "Created by Auto-Fabric on Thu Jan 2 01:03:47 2014"
linkagg lacp agg 126 actor admin-key 65534
linkagg lacp agg 127 size 16 hash tunnel-protocol admin-state enable
linkagg lacp agg 127 name "Created by Auto-Fabric on Thu Jan 2 00:52:38 2014"
linkagg lacp agg 127 actor admin-key 65535
. . .

mgmtsw-101# show linkagg agg 126

Dynamic Aggregate
SNMP Id : 40000126,
Aggregate Number : 126,
SNMP Descriptor : Dynamic Aggregate Number 126 ref 40000126 size 16,
Name : Created by Auto-Fabric on Thu Jan 2 01:03:47 2014,
Admin State : ENABLED,
Operational State : DOWN,
Aggregate Size : 16,
Number of Selected Ports : 0,
Number of Reserved Ports : 0,
Number of Attached Ports : 0,
Primary Port : NONE,
Port Selection Hash : Tunnel-Protocol,
Wait To Restore Time : 0 Minutes
LACP
MACAddress : [00:00:00:00:00:00],
Actor System Id : [00:00:00:00:00:00],
Actor System Priority : 0,
Actor Admin Key : 65534,
Actor Oper Key : 0,
Partner System Id : [00:00:00:00:00:00],
Partner System Priority : 0,
Partner Admin Key : 0,
Partner Oper Key : 0

mgmtsw-101# show linkagg agg 123

Dynamic Aggregate
SNMP Id : 40000123,
Aggregate Number : 123,
SNMP Descriptor : Dynamic Aggregate Number 123 ref 40000123 size 16,
Name : Created by Auto-Fabric on Fri Feb 21 02:20:52 2014,
Admin State : ENABLED,
Operational State : DOWN,
Aggregate Size : 16,
Number of Selected Ports : 0,
Number of Reserved Ports : 0,
Number of Attached Ports : 0,
Primary Port : NONE,
Port Selection Hash : Tunnel-Protocol,
Wait To Restore Time : 0 Minutes
LACP
MACAddress : [94:24:e1:05:a2:ca],
Actor System Id : [00:00:00:00:00:00],
Actor System Priority : 0,
Actor Admin Key : 65531,
Actor Oper Key : 65531,
Partner System Id : [00:00:00:00:00:00],
Partner System Priority : 0,
Partner Admin Key : 0,
Partner Oper Key : 0

mgmtsw-101# show linkagg agg 124

Dynamic Aggregate
SNMP Id : 40000124,
Aggregate Number : 124,
SNMP Descriptor : Dynamic Aggregate Number 124 ref 40000124 size 16,
Name : Created by Auto-Fabric on Fri Feb 21 02:19:27 2014,
Admin State : ENABLED,
Operational State : DOWN,
Aggregate Size : 16,
Number of Selected Ports : 0,
Number of Reserved Ports : 0,
Number of Attached Ports : 0,
Primary Port : NONE,
Port Selection Hash : Tunnel-Protocol,
Wait To Restore Time : 0 Minutes
LACP
MACAddress : [94:24:e1:05:a6:6c],
Actor System Id : [00:00:00:00:00:00],
Actor System Priority : 0,
Actor Admin Key : 65532,
Actor Oper Key : 65532,
Partner System Id : [00:00:00:00:00:00],
Partner System Priority : 0,
Partner Admin Key : 0,
Partner Oper Key : 0

mgmtsw-101#

Am i missing something here?
There seems to be only one VC-Link up. But we have two connected. Is that normal behaivour?

mgmtsw-101# sh virtual-chassis vf-link
VFLink mode: Auto

Primary Config Active Def Speed
Chassis/VFLink ID Oper Port Port Port Vlan Type
-------------------+----------+---------+-------+-------+---------+-----------
1/0 Up 1/1/53 2 2 1 21G
2/0 Up 2/1/53 2 2 1 21G


mgmtsw-101# sh virtual-chassis auto-vf-link-port
Chassis/Slot/Port Chassis/VFLink ID VFLink member status
-------------------+------------------+--------------------
1/1/53 1/0 Up
1/1/54 1/0 Up
2/1/53 2/0 Up
2/1/54 2/0 Up

silvio
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 1393
Joined: 01 Jul 2008 10:51
Location: Germany

Re: Stacking Issiue?

Post by silvio » 27 Nov 2019 14:32

you should disable auto-fabric.
You can delete the autogenerated lag's
In a VC of two 6860 both the ports are summarized to one vfl because both links are between the same members. You see this in your port count of 2 in both vfl 0.
About the many info logs (not an error) I have no knowledge. Do you have the newest release installed?
regards
Silvio

pinnback
Member
Posts: 4
Joined: 01 Dec 2011 07:36

Re: Stacking Issiue?

Post by pinnback » 03 Dec 2019 07:51

Thanks silvio,

what IS the current release? There is no way to find out in the entire Internet :D

I have :

System:
Description: Alcatel-Lucent Enterprise OS6900-T20 8.5.196.R04 GA, February 25, 2019.,

silvio
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 1393
Joined: 01 Jul 2008 10:51
Location: Germany

Re: Stacking Issiue?

Post by silvio » 06 Dec 2019 13:53

8.6.299.R01
If you have no access to the business portal than you have to ask a alcatel partner (normaly the supplier of the switches...)
best regards
Silvio

Post Reply