Sending number between sip trunk to another T2 trunk

This is the main discussion forum, if the subject that you want to talk about is not listed around here.
Post Reply
Airwolf1977
Member
Posts: 1
Joined: 24 Oct 2019 04:06

Sending number between sip trunk to another T2 trunk

Post by Airwolf1977 »

Hi Everyone,
I've got a problem with an oxe to send a sequence received from a private sip trunk to public T2 line.

This sequence is a public number like 0 01xxxxxxxx. So the first 0 corresponding to an ars to send number to a t2 line.
On tcpdump with wireshark, oxe respond with 488 not acceptable here.

Any idea to fix the problem? I checked the connection cos between these two trunk and everything is fine.
haroun
Senior Member
Posts: 1355
Joined: 29 Mar 2010 11:09

Re: Sending number between sip trunk to another T2 trunk

Post by haroun »

trunk GROUP PNC
a classic transit case , check if the private sip trunk is allowed to call and to connect with public trunk group
Post Reply

Return to “MAIN”