Beginners Question

Post Reply
Telefonguy
Member
Posts: 3
Joined: 19 Jun 2022 08:27

Beginners Question

Post by Telefonguy »

Hello,

i have a Alcatel Omnipcx Enterprice from one of our customers. But i have no idea how i should configure it.

Alize BIOS Monitor
*** BIOS Version 3EH30227ALAC bios100/011.003 ***
*** Generated on Dec/16/2008 at 11:27 ***

I try OMC 51.0.8.1 but i cant connect. (final product ist turned to OXO connect R1-R51 ADE100)

PC over Switch in (Gateway driver Processing Unit) Port LAN

Config Cable on Config Port

I can see the ip of the Unit, but when i turned my PC in the same IP Range i cant ping it and i cant connect to the pbx via OMC.

What is wrong?
vad
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 3807
Joined: 23 Sep 2004 06:47

Re: Beginners Question

Post by vad »

At first - we talk about OXO (and OMC) or about Enterprise (and telnet connection with CS).
Telefonguy
Member
Posts: 3
Joined: 19 Jun 2022 08:27

Re: Beginners Question

Post by Telefonguy »

Oh, i see my mistake. You are correct this one is a Enterprise. So i have to use the CS.
haroun
Senior Member
Posts: 1355
Joined: 29 Mar 2010 11:09

Re: Beginners Question

Post by haroun »

and how did u get those info if you aren't connected to the box
Alize BIOS Monitor
*** BIOS Version 3EH30227ALAC bios100/011.003 ***
*** Generated on Dec/16/2008 at 11:27 ***
vad
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 3807
Joined: 23 Sep 2004 06:47

Re: Beginners Question

Post by vad »

haroun wrote: 21 Jun 2022 06:03 and how did u get those info if you aren't connected to the box
Alize BIOS Monitor
*** BIOS Version 3EH30227ALAC bios100/011.003 ***
*** Generated on Dec/16/2008 at 11:27 ***
Serial connection to console port of GD?
haroun
Senior Member
Posts: 1355
Joined: 29 Mar 2010 11:09

Re: Beginners Question

Post by haroun »

indded vad that should serial connection , so he can start from here
about that bios message i don't know if it's cs bios or gd , if cs he has to boot the system and manage his pc @ipadress to trust list and eventually routing to get connection and let oxe to response to its telnet requests
vad
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 3807
Joined: 23 Sep 2004 06:47

Re: Beginners Question

Post by vad »

haroun wrote: 21 Jun 2022 09:15 indded vad that should serial connection , so he can start from here
about that bios message i don't know if it's cs bios or gd , if cs he has to boot the system and manage his pc @ipadress to trust list and eventually routing to get connection and let oxe to response to its telnet requests
From start post "Config Cable on Config Port"
So I think that in the begining TC start works with OXE like with OXO. I hope - he has no problem now.
Post Reply

Return to “Beginner's questions about the (4400 / Enterprise) PHONE APPLICATION or OPERATING SYSTEM”