Config users_lines is not ok! (tsa_maintenance)

Post by nowi_DUP » 02 Jul 2008 04:25

Hi,

using tsa_maintenance I always see "Config users_lines is not ok".

What does this mean?

I could do a 57 Force loading users and when adding a UC user the correct info in added in OTUC.

I just want to know if this is a problem or not. Call me "overcautious".

Ciao,
Nowi

User avatar
cavagnaro
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 6566
Joined: 14 Sep 2005 19:45
Location: Brasil, Porto Alegre
Contact:

Re: Config users_lines is not ok! (tsa_maintenance)

Post by cavagnaro » 02 Jul 2008 05:10

I always had that when I forgot to apply (confirming) data on Call Server. After doing it (click apply) and a restart "problem" was gone...
Ignorance is not the problem, the problem is the one who doesn't want to learn

OTUC/ICS ACFE/ACSE R3.0/4.0/5.0/6.0
Certified Genesys CIV 8.5
Certified Genesys Troubleshooting 8.5
Certified Genesys BEP 8.x
Genesys Developer

nowi_DUP
Member
Posts: 113
Joined: 10 Dec 2007 09:27
Location: Graz, Austria

Re: Config users_lines is not ok! (tsa_maintenance)

Post by nowi_DUP » 02 Jul 2008 06:14

Hmmm...

did not work for me....

The only Alarm I see is PBX MNGT Service

Problem during start PMS due to problem with DataAccess or Acapi.

have to say that this is a HA installation and the STDBY Server is not yet running. This will be done by Pro Services later on.

Nowi

User avatar
cavagnaro
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 6566
Joined: 14 Sep 2005 19:45
Location: Brasil, Porto Alegre
Contact:

Re: Config users_lines is not ok! (tsa_maintenance)

Post by cavagnaro » 23 Oct 2014 15:43

I know very old post, but fix to this is reinstall ACAPI.
Ignorance is not the problem, the problem is the one who doesn't want to learn