INCIDENT MANAGER
This object is used to declare the local RMA and define the global parameters concerning feedback of incidents. (mailsys.).
Set RMA Default
This command is used to reset the default RMA configuration for the generic filters
Set SNMP Default
Creation of filters by default for SNMP incidents
Set Network incident Default
Creation of filters by default for CMISE incidents
Delete SNMP Default
Deletion of filters by default for SNMP incidents
Delete Network incident Default
Deletion of filters by default for CMISE incidents
Delete RMA Default
This action is used to delete the RMA incident filters created by default.
By default, the RMA incidents are in the file /DHS3data/incid/rma.txt
Instance (reserved)
V24 No.
Number of the V24 incident display port.
The menu choices correspond to:
- _/dev/ttyS0, _/dev/ttyS1, _/dev/ttyS2, _/dev/ttyS3 : ports V24 A to D of the CPU,
- ttyspb01a to ttyspb11a: socket 1 to 11 of the IO2 board (equipped as daughter board SPB),
- io2tty01 to 30: fictitious ports corresponding to B channels of the IO2:
- if these ports are declared statically: a calling user, who must be TA V120, connnects to a CPU application using the corresponding Directory No. (see Port Directory No.),
- if these ports are declared dynamically: when a user dials an application, the port is selected dynamically from all the dynamic ports (between 0 and 44) depending on the characteristics of the calling party and the availability of the ports.
RMA
This attribute indicates the presence of a local RMA and/or a local eRMA
RMA Network
YES: send incidents from the network to the local RMA
Display Severity
Minimum severity above which the incidents are displayed unless an incident filter requests otherwise.
Storage Severity
Minimum severity above which the incidents are stored unless an incident filter requests otherwise.
Network Severity
Minimum severity above which the incidents are fed back in the network unless an incident filter requests otherwise.
Network Incident Display Severity
Minimum severity above which the network incidents are displayed.
Network Incident Storage Severity
Minimum severity above which the network incidents are stored.
Topological Incident Display
YES: display of topological incidents (local and network)
Topological Incident Storage
YES: storage of topological incidents (local and network)
Topological Network
YES: feedback in the network of local topological incidents.
SNMP
Attribute used to manage transmission of incidents to the SNMP application according to their type or level of severity.
Severity
This attribute determines the minimum severity level according to which local incidents are transmitted to the SNMP application.
Network Severity
If Network is set to YES, this attribute determines the severity level according to which local incidents are transmitted to the SNMP application.
Network Severity
Topology
YES: topology incidents are transmitted to the SNMP application.
RMA
YES: RMA incidents are transmitted to the SNMP application.
Network
YES: network incidents are transmitted to the SNMP application (see Network Severity).