Hello,
We have start the maintenance over a OXE 12.3 with 500 users, which has the wrong callserver board type after upgrade from Rel 10.0 to 12.3. :?
Is it possible to change the board type from CS to CS3 on a running OXE 12.3 without any problems?
How is the correct way to change the board type ...
Search found 14 matches
- 17 Mar 2020 18:19
- Forum: Shelf
- Topic: Change Interface Type CS to CS3 OXE 12.3
- Replies: 1
- Views: 9243
- 21 Sep 2017 11:32
- Forum: PARTS
- Topic: For sale: Worldwide OXE Rel 11, MG's with Common HW and IP Phones
- Replies: 1
- Views: 2900
For sale: Worldwide OXE Rel 11, MG's with Common HW and IP Phones
Worldwide OXE System for sale!
The OXE was installed between 2013 - 2015
For detailed information please contact me.
Mediagateways
each Mediagateway 3 (Large) with GD3, PCS and some Boards, mostly 1x UAI8/UAI16, 1x SLI8/SLI16 and PRA-T1/T2, BRA2 or APA8.
--> Austria 6x MG3
--> Germany 2x MG3 ...
The OXE was installed between 2013 - 2015
For detailed information please contact me.
Mediagateways
each Mediagateway 3 (Large) with GD3, PCS and some Boards, mostly 1x UAI8/UAI16, 1x SLI8/SLI16 and PRA-T1/T2, BRA2 or APA8.
--> Austria 6x MG3
--> Germany 2x MG3 ...
- 21 Sep 2017 11:32
- Forum: PARTS
- Topic: For sale: Worldwide OXE Rel 11, MG's with Common HW and IP Phones
- Replies: 0
- Views: 2892
For sale: Worldwide OXE Rel 11, MG's with Common HW and IP Phones
Worldwide OXE System for sale!
The OXE was installed between 2013 - 2015
For detailed information please contact me.
Mediagateways
each Mediagateway 3 (Large) with GD3, PCS and some Boards, mostly 1x UAI8/UAI16, 1x SLI8/SLI16 and PRA-T1/T2, BRA2 or APA8.
--> Austria 6x MG3
--> Germany 2x MG3 ...
The OXE was installed between 2013 - 2015
For detailed information please contact me.
Mediagateways
each Mediagateway 3 (Large) with GD3, PCS and some Boards, mostly 1x UAI8/UAI16, 1x SLI8/SLI16 and PRA-T1/T2, BRA2 or APA8.
--> Austria 6x MG3
--> Germany 2x MG3 ...
- 29 Apr 2014 17:11
- Forum: SIP
- Topic: OXE to Polycom DMA7000 via SIP or H323
- Replies: 1
- Views: 1584
OXE to Polycom DMA7000 via SIP or H323
Hello,
has anyone connected a OXE Rel 10.1.1 to a Polycom DMA7000 unit, to use the virtual conference rooms of the polycom?
I have spoken with ALU, but they haven't an interworking report for that.
maybe someone can help me
best regards,
Harry
has anyone connected a OXE Rel 10.1.1 to a Polycom DMA7000 unit, to use the virtual conference rooms of the polycom?
I have spoken with ALU, but they haven't an interworking report for that.
maybe someone can help me
best regards,
Harry
- 12 Feb 2014 15:14
- Forum: OmniAccess WLAN Switching Systems (OEM)
- Topic: OmniAccess 4306GW factory default
- Replies: 6
- Views: 10452
Re: OmniAccess 4306GW factory default
Hi Silvio,
thanks for your help, but I doesn't have the password to login with the admin account. Is there another way to set the 4306GW to the factory default?
Harry
thanks for your help, but I doesn't have the password to login with the admin account. Is there another way to set the 4306GW to the factory default?
Harry
- 12 Feb 2014 05:38
- Forum: OmniAccess WLAN Switching Systems (OEM)
- Topic: OmniAccess 4306GW factory default
- Replies: 6
- Views: 10452
OmniAccess 4306GW factory default
Hi,
how I can set the 4306GW to the factory default?
#write erase doesn't work :(
-------------------------------------------------------------------
CPBoot 1.0.0.0 (build 23274)
Built: 2010-01-19 at 11:11:22
DDR2 DRAM running at 466Mhz
DRAM: Total = 512 MB
POST: Memory test: Physical 0 ...
how I can set the 4306GW to the factory default?
#write erase doesn't work :(
-------------------------------------------------------------------
CPBoot 1.0.0.0 (build 23274)
Built: 2010-01-19 at 11:11:22
DDR2 DRAM running at 466Mhz
DRAM: Total = 512 MB
POST: Memory test: Physical 0 ...
- 15 Mar 2013 19:02
- Forum: Groups
- Topic: Cannot Add Users to new created Hunt Group
- Replies: 8
- Views: 8287
Re: Cannot Add Users to new created Hunt Group
Hi,
you can write the hunting group number in the user who should inside this group
User/hunting group directory number => 1000
Bye
Harry
you can write the hunting group number in the user who should inside this group
User/hunting group directory number => 1000
Bye
Harry
- 18 Feb 2013 16:24
- Forum: Attendant
- Topic: 4039, 4029, 4020 & Dect 400 in Attendant Group
- Replies: 2
- Views: 2794
Re: 4039, 4029, 4020 & Dect 400 in Attendant Group
Yeah it work's fine 
Thanks tot3nkopf
Thanks tot3nkopf
- 14 Feb 2013 19:54
- Forum: Attendant
- Topic: 4039, 4029, 4020 & Dect 400 in Attendant Group
- Replies: 2
- Views: 2794
4039, 4029, 4020 & Dect 400 in Attendant Group
Hi,
i've to solve a special task :)
the customer have an "dynamic attendant place" (the woman by the attendant is not all time on the place). So other people in the offices around the attendant place must pickup the attendant calls with their sets (4039, 4029, 4020 & Dect 400).
Now i had 2 ...
i've to solve a special task :)
the customer have an "dynamic attendant place" (the woman by the attendant is not all time on the place). So other people in the offices around the attendant place must pickup the attendant calls with their sets (4039, 4029, 4020 & Dect 400).
Now i had 2 ...
- 24 Mar 2011 08:15
- Forum: MAIN
- Topic: Second Callback Oxo Rel. 5.1
- Replies: 2
- Views: 2176
Re: Second Callback Oxo Rel. 5.1
OK thx for your answer
Harry
Harry