Hi,
you're right. I made a mistake. The correct configuration is:
netadmin –m
Routing
Static route
Add/update
Destination type ? h
Destination IP address: 10.253.1.10
Gateway IP address: 172.30.253.1
In the static route configuration, try to put the subnetmask like this: 255.255.255.0
Search found 8 matches
- 29 Nov 2013 04:51
- Forum: X25
- Topic: X25 through OV 4760
- Replies: 17
- Views: 24459
- 28 Nov 2013 03:12
- Forum: X25
- Topic: X25 through OV 4760
- Replies: 17
- Views: 24459
Re: X25 through OV 4760
Hi,
1st you have to declare node 1 on your Omnivista 4760: (main parameters)
node number: (ABC network number * 100 + node number): in your case, 1
IP address: Main IP address: 10.253.1.3
Connection Type: LAN
Next you have to declare your Node 2 on your Omnivista 4760: (main parameters)
node ...
1st you have to declare node 1 on your Omnivista 4760: (main parameters)
node number: (ABC network number * 100 + node number): in your case, 1
IP address: Main IP address: 10.253.1.3
Connection Type: LAN
Next you have to declare your Node 2 on your Omnivista 4760: (main parameters)
node ...
- 06 Sep 2011 04:25
- Forum: SIP
- Topic: SIP redundancy
- Replies: 13
- Views: 8030
Re: SIP redundancy
Hi,
check the trunk COS of your SIP Trunk group. (It should be 31). Then in External services -> Trunk COS 31 try to play with parameter Timer T310 (by default 20s).
This is the timer use to overflow from one route to another one in ARS table.
check the trunk COS of your SIP Trunk group. (It should be 31). Then in External services -> Trunk COS 31 try to play with parameter Timer T310 (by default 20s).
This is the timer use to overflow from one route to another one in ARS table.
- 17 Dec 2010 11:00
- Forum: Trunk Groups
- Topic: German T2 Trunk Group
- Replies: 1
- Views: 1497
German T2 Trunk Group
Hi,
next week, I'll have to configure a T2-E1 Trunk Group in Germany. I would like to know if there is something different ( specific) from the basic configuration that we can find in the Alcatel OXE documentation.
thanks a lot.
next week, I'll have to configure a T2-E1 Trunk Group in Germany. I would like to know if there is something different ( specific) from the basic configuration that we can find in the Alcatel OXE documentation.
thanks a lot.
- 14 Dec 2010 10:14
- Forum: Application
- Topic: Agent Sets
- Replies: 7
- Views: 3483
Re: Agent Sets
you're right Vad. You can use 4039 as agent only from R7.0
- 14 Dec 2010 03:14
- Forum: Application
- Topic: Agent Sets
- Replies: 7
- Views: 3483
Re: Agent Sets
hi Xero,
as pro-acd set for an agent, you can use Analog set, 4004, 4035, 4037, 4038, 4039 and 4068.
as pro-acd set for a supervisor, you can use 4035, 4037, 4038, 4039 and 4068.
Bye
as pro-acd set for an agent, you can use Analog set, 4004, 4035, 4037, 4038, 4039 and 4068.
as pro-acd set for a supervisor, you can use 4035, 4037, 4038, 4039 and 4068.
Bye
- 30 Nov 2010 03:38
- Forum: X25
- Topic: X25 through OV 4760
- Replies: 17
- Views: 24459
Re: X25 through OV 4760
Hi Mustafa,
did you declare your first node as gateway link when you set the 2nd node in the system directory?
You also need to create a static route (using netadmin) in the 2nd node to be able to join the first one through IP/X25 tunnel.
BR
did you declare your first node as gateway link when you set the 2nd node in the system directory?
You also need to create a static route (using netadmin) in the 2nd node to be able to join the first one through IP/X25 tunnel.
BR
- 23 Nov 2010 05:16
- Forum: Configuration
- Topic: Pilot delete failed
- Replies: 3
- Views: 2510