469 G723.1 Server = 174
+===============================================================================+
| C O M P V I S U L I O |
+===============================================================================+
| cr | cp | type dsp | coupler state | H323 Gateway |
| | | | | for direct RTP ...
Search found 16 matches
- 14 Mar 2014 09:16
- Forum: Media Gateway
- Topic: No more TS between CR X and CR Y or no more conference
- Replies: 13
- Views: 13029
- 14 Mar 2014 08:47
- Forum: Media Gateway
- Topic: No more TS between CR X and CR Y or no more conference
- Replies: 13
- Views: 13029
Re: No more TS between CR X and CR Y or no more conference
It's very hard to delete and recreate board because of active users.
I created a new shelf 10 and registered a GD3 board with it but the result was the same - there is no available compressors
I created a new shelf 10 and registered a GD3 board with it but the result was the same - there is no available compressors
- 14 Mar 2014 07:50
- Forum: Media Gateway
- Topic: No more TS between CR X and CR Y or no more conference
- Replies: 13
- Views: 13029
Re: No more TS between CR X and CR Y or no more conference
Yes, sure, I rebooted it
I can use just old GD board. We have no more GD3 boards
I can use just old GD board. We have no more GD3 boards
- 14 Mar 2014 07:10
- Forum: Media Gateway
- Topic: No more TS between CR X and CR Y or no more conference
- Replies: 13
- Views: 13029
Re: No more TS between CR X and CR Y or no more conference
I'll try to do a 3-way conference at the next monday.
I have 0 default ip domain with next configuration
+-Review/Modify: IP domain--------------------------------------------------------------+
| |
| Node Number (reserved) : 59 |
| Instance (reserved) : 1 |
| IP Domain Number : 0 |
| |
| IP ...
I have 0 default ip domain with next configuration
+-Review/Modify: IP domain--------------------------------------------------------------+
| |
| Node Number (reserved) : 59 |
| Instance (reserved) : 1 |
| IP Domain Number : 0 |
| |
| IP ...
- 14 Mar 2014 06:37
- Forum: Media Gateway
- Topic: No more TS between CR X and CR Y or no more conference
- Replies: 13
- Views: 13029
Re: No more TS between CR X and CR Y or no more conference
Thank you for replay
That is additional data
14/03/14 16:31:00 000059M|002/06/0/000|=4:2011=No more TS between CR 2 and CR 3 or no more conference resources
14/03/14 16:31:01 000059M|002/06/0/000|=4:2011=No more TS between CR 2 and CR 3 or no more conference resources
14/03/14 16:31:01 000059M|002 ...
That is additional data
14/03/14 16:31:00 000059M|002/06/0/000|=4:2011=No more TS between CR 2 and CR 3 or no more conference resources
14/03/14 16:31:01 000059M|002/06/0/000|=4:2011=No more TS between CR 2 and CR 3 or no more conference resources
14/03/14 16:31:01 000059M|002 ...
- 14 Mar 2014 05:11
- Forum: Media Gateway
- Topic: No more TS between CR X and CR Y or no more conference
- Replies: 13
- Views: 13029
No more TS between CR X and CR Y or no more conference
Hi all.
After migrating from GD and MEX to GD3 and PowerMEX I have a problem with one media gateway.
I have multiple incidents
2011=No more TS between CR X and CR Y or no more conference resources
I've look at GD3 board in 3 media gateway and seen that there is no any available compressors ...
After migrating from GD and MEX to GD3 and PowerMEX I have a problem with one media gateway.
I have multiple incidents
2011=No more TS between CR X and CR Y or no more conference resources
I've look at GD3 board in 3 media gateway and seen that there is no any available compressors ...
- 25 Feb 2014 02:36
- Forum: 4760
- Topic: OmniVista 4760 change IP
- Replies: 12
- Views: 13340
Re: OmniVista 4760 change IP
thanks to all
Update: seems everthing is OK
Update: seems everthing is OK
- 24 Feb 2014 05:13
- Forum: 4760
- Topic: OmniVista 4760 change IP
- Replies: 12
- Views: 13340
OmniVista 4760 change IP
Hi
Are there any instructions or procedure to change IP address on OmniVista server ?
Are there any instructions or procedure to change IP address on OmniVista server ?
- 22 Feb 2013 03:54
- Forum: MAIN
- Topic: CPU6 to Appliance server migration
- Replies: 3
- Views: 2500
Re: CPU6 to Appliance server migration
Thank you Vad.
I succesfully migrated to Appliance server but one duplicating INTOF2 board somehow stoped works.
It tries to load binary and after that there is the incident 2507=Dow: message badly received by thread -8 and it goes to outserv.
After that there is no any possibility to reset board.
I ...
I succesfully migrated to Appliance server but one duplicating INTOF2 board somehow stoped works.
It tries to load binary and after that there is the incident 2507=Dow: message badly received by thread -8 and it goes to outserv.
After that there is no any possibility to reset board.
I ...
- 22 Feb 2013 03:37
- Forum: Inter-Node Links
- Topic: Hybrid link problem
- Replies: 3
- Views: 4506
Re: Hybrid link problem
Thank u, Alex.
I reduced the number of hybrid links with dynamic routing (changed to static routing) and the problem seems was resolved.
How many nodes with hybrid links with dynamic routing may I have?
I reduced the number of hybrid links with dynamic routing (changed to static routing) and the problem seems was resolved.
How many nodes with hybrid links with dynamic routing may I have?