Hello
i have a problem with Numb. of sig. channels inter-ACT while adding GD card to com server that this value is 0 in this GD card while it is 1 in all other GD's. can you help me to understand what is the problem?
BR
Adel
Search found 6 matches
- 20 May 2023 13:06
- Forum: System
- Topic: error in DB after installation of OXE software 12.4
- Replies: 2
- Views: 5001
- 11 Dec 2021 07:46
- Forum: System
- Topic: error in DB after installation of OXE software 12.4
- Replies: 2
- Views: 5001
error in DB after installation of OXE software 12.4
Dears
I have this error when run checkdb command
checkdb
Data base checking in progress ...
/..............................ERROR 4351 : DATA INCONSISTENCY, Table NETNODE, Bad local Node in TunParams=0
can any one help me?
BR
I have this error when run checkdb command
checkdb
Data base checking in progress ...
/..............................ERROR 4351 : DATA INCONSISTENCY, Table NETNODE, Bad local Node in TunParams=0
can any one help me?
BR
- 08 Nov 2021 02:34
- Forum: Lucent Technologies
- Topic: standard installation oxe 12.4 version M5.20480f
- Replies: 3
- Views: 6649
Re: standard installation oxe 12.4 version M5.20480f
yes, i tried to install it by using SOT and PC installer but it gives same error
- 07 Nov 2021 03:21
- Forum: Lucent Technologies
- Topic: standard installation oxe 12.4 version M5.20480f
- Replies: 3
- Views: 6649
standard installation oxe 12.4 version M5.20480f
Dears,
I tried to install OXE 12.4 on HP server proliant DL20 Gen9 by using SOT. The installation complete as per SOT message. On the other hand, when server switched on the below message appear
"attempting boot from hard drive (c:) "
Grub loading stage 2. output on the serial line ..
Thanks in ...
I tried to install OXE 12.4 on HP server proliant DL20 Gen9 by using SOT. The installation complete as per SOT message. On the other hand, when server switched on the below message appear
"attempting boot from hard drive (c:) "
Grub loading stage 2. output on the serial line ..
Thanks in ...
- 07 Nov 2021 02:45
- Forum: Beginner's questions about the Common Hardware
- Topic: After activate clip in sli 16 1 telephone not ringing
- Replies: 2
- Views: 3395
Re: After activate clip in sli 16 1 telephone not ringing
Thanks frank
the problem solved by changing parameter. i checked old posts here and i found necessary parameters
the problem solved by changing parameter. i checked old posts here and i found necessary parameters
- 23 Aug 2021 13:39
- Forum: Beginner's questions about the Common Hardware
- Topic: After activate clip in sli 16 1 telephone not ringing
- Replies: 2
- Views: 3395
After activate clip in sli 16 1 telephone not ringing
I activated clip feature for sli 16 1 but unfortunately telephone didn’t ring while all dynamic init parameters set to be 255.is anybody know values to be set in dynamic init parameters.note I can pickup call while telephone didn’t ring.
Thanks in advance
Thanks in advance