Search found 7 matches
- 04 Apr 2024 07:38
- Forum: 7750 SR
- Topic: admin display-config AND paging disabled - HOW TO DO IT?
- Replies: 2
- Views: 14508
- 23 Sep 2022 03:04
- Forum: OmniSwitch 6860 / 6860E
- Topic: Safely remove Master chassis from stack?
- Replies: 2
- Views: 2291
Re: Safely remove Master chassis from stack?
Thank you very much Silvio. Much appreciated.
- 22 Sep 2022 07:59
- Forum: OmniSwitch 6860 / 6860E
- Topic: Safely remove Master chassis from stack?
- Replies: 2
- Views: 2291
Safely remove Master chassis from stack?
Good day Guys,
I need to shutdown and remove the master chassis from the OS6860E switch stack. What is the safest way of removing the master?
Can I just do command, virtual-chassis shutdown , and then physically remove the chassis ?
Thank you,
<<< Stack info >>>
-> sh chassis
Local Chassis ID 1 ...
I need to shutdown and remove the master chassis from the OS6860E switch stack. What is the safest way of removing the master?
Can I just do command, virtual-chassis shutdown , and then physically remove the chassis ?
Thank you,
<<< Stack info >>>
-> sh chassis
Local Chassis ID 1 ...
- 08 Apr 2020 08:18
- Forum: 7750 SR
- Topic: BFD Session Limit - 50 ?
- Replies: 3
- Views: 27457
Re: BFD Session Limit - 50 ?
Answer found. in 'show log log-id 99' :?
247100118 2020/04/08 13:28:28.21 SAST MAJOR: VRTR #2013 Base Max supported sessions reached
"The number of BFD sessions on cpm 0 has exceeded 50, constrained by maxSessionsPerSlot "
Our model is a 7750 SR-c12. It would seem that the limit on 7750 SR-c12 ...
247100118 2020/04/08 13:28:28.21 SAST MAJOR: VRTR #2013 Base Max supported sessions reached
"The number of BFD sessions on cpm 0 has exceeded 50, constrained by maxSessionsPerSlot "
Our model is a 7750 SR-c12. It would seem that the limit on 7750 SR-c12 ...
- 08 Apr 2020 04:25
- Forum: 7750 SR
- Topic: BFD Session Limit - 50 ?
- Replies: 3
- Views: 27457
BFD Session Limit - 50 ?
Good day Everyone,
Hope everybody is safe during this interesting times around Covid-19.
I want to hear if anybody has run into a problem where there seems to be a limit of 50 bfd session on the Nokia 7750 routers?
We have 96 bfd sessions configured, but only 50 seems to be active ?
Kind regards,
Hope everybody is safe during this interesting times around Covid-19.
I want to hear if anybody has run into a problem where there seems to be a limit of 50 bfd session on the Nokia 7750 routers?
We have 96 bfd sessions configured, but only 50 seems to be active ?
Kind regards,
- 05 Mar 2020 07:54
- Forum: 7750 SR
- Topic: Is there an MIB for the 7750?
- Replies: 3
- Views: 11567
Re: Is there an MIB for the 7750?
There are lots of MIBs for the 7750.
There is a MIBs folder in the zip file in which the SR OS software is distributed.
You may also find older versions on the web.
For example, the MIBs with filenames starting with "TIMETRA-" here:
https://github.com/pgmillon/observium/tree/master/mibs/aos ...
- 02 Mar 2020 03:00
- Forum: 7705 SAR
- Topic: Link Quality test - Backhauls
- Replies: 1
- Views: 13648
Link Quality test - Backhauls
Good day Everyone,
I'm fairly new to the Alcatel / Nokia Networking world. Previously only working on the Cisco Side.
My new Company runs Alcatel 7705 SAR-A routers on our edge. over 100 Routers. At the Datacenters side we have 7750 SR-c12.
I'm trying to understand what is the best way for us to ...
I'm fairly new to the Alcatel / Nokia Networking world. Previously only working on the Cisco Side.
My new Company runs Alcatel 7705 SAR-A routers on our edge. over 100 Routers. At the Datacenters side we have 7750 SR-c12.
I'm trying to understand what is the best way for us to ...