Search found 2 matches

by mkerem1
03 Feb 2025 01:05
Forum: OmniSwitch 6900
Topic: Spantree loops
Replies: 2
Views: 1808

Re: Spantree loops

Thanks for reply,

We have solved the problem. When I checked building switch configs, Flat mode not defined.
And also I changed priorities of spantrees. Then it worked properly (As you said)
Thanks for your interest..
by mkerem1
31 Jan 2025 07:24
Forum: OmniSwitch 6900
Topic: Spantree loops
Replies: 2
Views: 1808

Spantree loops

Hi all,

In a large project that we are trying to put into operation, we are using Alcatel products. As can be seen in the attached drawing, OS6900 series backbones are used in two separate locations defined by VRRP in the system. There are two rings between the two backbones, one going over the ...

Go to advanced search