E1 interface coonection Maximum cable distance for CAT6A
-
HUSSAINQCS
E1 interface coonection Maximum cable distance for CAT6A
an anybody tell me we are having oxe one side and avaya other side we want to connect the both pabx through E1 interface (PRA-T2) just connecting PRAT2 PBX port to avaya PBX PRA card and the distance between two PABX is 280 m with CAT6A for interconnecting two E1 interfaces cable will it work ?
Re: E1 interface coonection Maximum cable distance for CAT6A
8AL91023USAG - Ed. 01 - April 2017 - OXE System: Cables
page 118
regards...
--- back to basics... focus your eyes to the essential things... ---
page 118
regards...
--- back to basics... focus your eyes to the essential things... ---
--- back to basics... focus your eyes to the essential things... ---
-
HUSSAINQCS
Re: E1 interface coonection Maximum cable distance for CAT6A
Is it possible to connect OXE PRA and AVAYA PRA with CAT6A cable without any E1 modem as intermediate When the distance between both PABX around 300 m
If so what are the cable pairs for Tx & Rx
If so what are the cable pairs for Tx & Rx
Re: E1 interface coonection Maximum cable distance for CAT6A
Hi
It might work due to the quality of cable. Altough technical documentation refers to 300 m max length for this kind of interface. The quality of cable will be the key for this kind of connection. But I would not do it. Have you ever thought about fiber media converter or SIP trunk?
Best regards.
It might work due to the quality of cable. Altough technical documentation refers to 300 m max length for this kind of interface. The quality of cable will be the key for this kind of connection. But I would not do it. Have you ever thought about fiber media converter or SIP trunk?
Best regards.
Enio Eltz Filho
ACFE OXE R12
ACFE OXO C R3
ACFE OXE R12
ACFE OXO C R3
Re: E1 interface coonection Maximum cable distance for CAT6A
Hi !
The E1 is carried over a G703 line, specs. is around 1000-1200 m , We have succesfully running a crystal over this for many years. BUT be aware of
the overvoltage in BOTH ends of the cable to protect the system and the cable.
Regards ...
/S
The E1 is carried over a G703 line, specs. is around 1000-1200 m , We have succesfully running a crystal over this for many years. BUT be aware of
the overvoltage in BOTH ends of the cable to protect the system and the cable.
Regards ...
/S
Re: E1 interface coonection Maximum cable distance for CAT6A
hi stefanc,
thanks for sharing!
which cable type do you use?
regards...
--- back to basics... focus your eyes to the essential things... ---
thanks for sharing!
which cable type do you use?
regards...
--- back to basics... focus your eyes to the essential things... ---
--- back to basics... focus your eyes to the essential things... ---
Re: E1 interface coonection Maximum cable distance for CAT6A
Hi !
We use a twisted pair of normal telecom std (0.7 mm DC- 1Mhz with prot. shield and self sealing for evt. water damage) will do.
But we used a 10 pair cable for mechanic strenght and took 2 non adjacent pairs from the pack. It had a outer shield that we connected to the (metal)protected earth. (same point as the grounding of the lightning protectors).
Regards ...
/S
We use a twisted pair of normal telecom std (0.7 mm DC- 1Mhz with prot. shield and self sealing for evt. water damage) will do.
But we used a 10 pair cable for mechanic strenght and took 2 non adjacent pairs from the pack. It had a outer shield that we connected to the (metal)protected earth. (same point as the grounding of the lightning protectors).
Regards ...
/S
-
HUSSAINQCS
Re: E1 interface coonection Maximum cable distance for CAT6A
But we can connect with Both PRA by CAT6A cable (1,2 Tx pairs,4,5 Rx pairs ) oxe side and avaya side (4,5 Tx pairs,1,2 Rx pairs )where distance between two pabx more tan 280 m
Re: E1 interface coonection Maximum cable distance for CAT6A
Yepp, indoors no problem, but outdoors , cable in the ground no no. Still it is advised to protect the cable/eq. for overvoltage. So use a CAT6E.