OmniSwitch 9900: how to increase log retention

Post Reply
alocatelli
Member
Posts: 2
Joined: 04 Oct 2022 05:55

OmniSwitch 9900: how to increase log retention

Post by alocatelli »

Hello everyone,
I should increase the log retention of an Omniswitch 9900.
Currently the logs are stored in the flash.

Code: Select all

9900 > show swlog
Operational Status                 : Running,
File Size per file                 : 1250 Kbytes,
Log Device 1                       : console flash,
Syslog FacilityID                  : local0(16),
Hash Table entries age limit       : 60 seconds,
Switch Log Preamble                : Enabled,
Switch Log Debug                   : Disabled,
Switch Log Duplicate Detection     : Enabled,
Console Display Level              : info,
RFC5424 Format Logging             : Disabled,
Swlog Threshold                    : 90 percent
Is it enough to increase the maximum size of the log files to increase the retention?
How can I verify the size of the flash?
Thank you in advance for your answers.
silvio
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 1886
Joined: 01 Jul 2008 10:51
Location: Germany

Re: OmniSwitch 9900: how to increase log retention

Post by silvio »

swlog output flash-file-size 12500 slot all (in kByte)
Post Reply