Hello
we have an oxe under R9.1 and at the moment I don't know what's going on.
Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|----|----|------------|-----------|--------------|-----------------|
| 0 | 6 | CPU_CS2|---------- | IN SERVICE | BAD PCMS CODE |
+-------------------------------------------------------------------+
> Reference rack not set
Crystal 1 :
+-------------------------------------------------------------------+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|----|----|------------|-----------|--------------|-----------------|
| 1 | 0 | UA_FICTIF| | IN SERVICE | NO PCMS CODE |
+-------------------------------------------------------------------+
Crystal 2 :
+-------------------------------------------------------------------+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|----|----|------------|-----------|--------------|-----------------|
| 2 | 0 | GD3|---------- | REG NOT INIT | BAD PCMS CODE |
| 2 | 1 | SLI2 16(Z)|---------- | REG NOT INIT | BAD PCMS CODE |
| 2 | 2 | UAI 16|---------- | REG NOT INIT | BAD PCMS CODE |
| 2 | 3 | SLI2 16(Z)|---------- | REG NOT INIT | BAD PCMS CODE |
| 2 | 4 | SLI2 16(Z)|---------- | REG NOT INIT | BAD PCMS CODE |
| 2 | 5 | SLI2 16(Z)|---------- | REG NOT INIT | BAD PCMS CODE |
| 2 | 6 | PRA T2|---------- | REG NOT INIT | BAD PCMS CODE |
| 2 | 7 | APA 8|---------- | REG NOT INIT | BAD PCMS CODE |
| 2 | 8 | CS2|---------- | CALL SERVER | BAD PCMS CODE |
+-------------------------------------------------------------------+
this is what I get in my ethernet settings
│
│ Node Number (reserved) : 3 │
│ Shelf Address : 2 │
│ Board Address : 0 │
│ Shelf - Board Address : 2-0 │
│ │
│ Interface Type + GD3 │
│ Board IP Address : 0.0.0.0 │
│ IP NetMask : 0.0.0.0 │
│ Default Gateway IP Address : 0.0.0.0 │
│ IP Quality of service : 0 │
│ Cryptographic box address : ----------------------------------------------- │
│ Board Ethernet Address : 00:80:9F:B5:7B:64 │
│ Interworking with Gatekeeper + NO │
│ Gatekeeper ID : -1 │
│ Numb. of sig. channels IP Phones : 0 │
│ Numb. of sig. channels inter-ACT : 0 │
│ IP Domain Number : 0 │
│ E164 Number List Index : -1 │
│ Gateway H323 name : -------------------------------- │
│
and when I try a reset on the GD3 I get an error message "SendCpl procedure error".
GD3 out
Re: GD3 out
do you think everyone sits on this board just waiting on questions from yourself ??? we dont get paid for advice and knowledge so calm down!!!!
Anyway have you actually plugged a cable onto the GD to see what is going on during boot, has the config been lost as it appears when you do a check on 2-0 there is no config on the GD
"Be aware ask a stupid question without at least trying to find the answer first you may get a stupid answer....."
Re: GD3 out
The first question - this is new added shelf or shelf 2 works before and now not working?
Check (as written before) - "what is going on during boot" with console cable plugged in GD.
Can you ping GD from CPU?
Check (as written before) - "what is going on during boot" with console cable plugged in GD.
Can you ping GD from CPU?
Re: GD3 out
hello and sorry sirsoldboy wrote: ↑10 Oct 2023 15:30
do you think everyone sits on this board just waiting on questions from yourself ??? we dont get paid for advice and knowledge so calm down!!!!
Anyway have you actually plugged a cable onto the GD to see what is going on during boot, has the config been lost as it appears when you do a check on 2-0 there is no config on the GD
we're currently connected in console mode and we're trying to restore the lost ip address
no, it's not an oxe 4400 but an oxe small
Re: GD3 out
VAD voulait te dire est ce que l'alveaole 2 est une nouvelle adjonction ou elle fonctionnait avant et s'est mise en arret?
verifier ce qui ne va pas' pendant le boot de la gd comme la suggérée oldboy
verifier ce qui ne va pas' pendant le boot de la gd comme la suggérée oldboy