"Error P1 on message type P2 on timeslot P3"

Are you having any trouble while you are configuring a 4400 on site ? Share it with us, maybe someone will have the solution !
Post Reply
Kinne_DUP

"Error P1 on message type P2 on timeslot P3"

Post by Kinne_DUP »

Hi,

recently there are many of those "Error P1 on message type P2 on timeslot P3" errors on my OmniPCX Enterprise 9.0

Detailled information is:

"Zusätzlicher Text Error 14 on message type 3 on timeslot 0
Information Fehlerdiagnose-Identifizierer: 4403
Diagnose "Error P1 on message type P2 on timeslot P3
P1 Error number
An error occurred during call setup or teardown
P1 :
- 1 : message size is wrong
- 2 : 8021Q parameters are missing
- 3 : bug in TLV
- 4 : timeslot is missing or is wrong in TLV
- 5 : message is not consistent
- 6 : transit is not available
- 7 : not enough resource on coupler
- 8 : unknown connection from cpu
if appears after CPU switch over, check up the CPU
- 9 : volume is too big
- 10: volume is too small
- 11: load problem - communication accepted
- 12: load problem - communication rejected
- 13: local communication release decision
- 14: message handling time too long => lost message
P2 :
- 1 : MSG_RTP_CONNECT - during com establishment
- 2 : MSG_VCOMP_SETUP - during voice parameters configuration
- 3 : MSG_RTP_DISCONNECT - during com disconnection
P3 : timeslot number in decimal
no reaction of the system
Check coupler binary and cpu compatibility if
P1 = 1,2,3,4,5,6.
Bug on coupler if P1 = 7,14.
Bug on cpu (due to switch over) if P1 = 8.
Check cpu parameter volume if P1 = 9,10.
"

Well, what does it actually want to tell me?
Kinne_DUP

Re: "Error P1 on message type P2 on timeslot P3"

Post by Kinne_DUP »

Also, some users have a problem.
]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]
Setup: external caller -----E1/S2m-----OmniPCX Ent 9.0-----IP-----------IP Touch 4028 EE]]]]]]]]]]]]]]]]]]]]]]]]]]]]
]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]\____E1/S2m____old PBX____local telephone exchange]
So, when a external caller calls that IP Touch, there´s no sound, nothing. He will be directly forwarded to the local telephone exchange, which is on our old PBX. One second later the caller calls again and is forwarded correctly to the IP Touch 4028 EE.

Well, I instructed some of those users to call me immediately when this happens. So they did. Afterwards I phoned the callees. They told me that they haven´t used they phones in that time. So no used phones. Also the phone ran normally (no reboot).

I am asking myself whether that error I mention above has something to do with this?
Recently I attached more and more users to the OmniPCX. But I assume that has nothing to do with it...?
User avatar
tot3nkopf
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 4058
Joined: 02 Feb 2006 10:41
Location: Germany & Romania
Contact:

Re: "Error P1 on message type P2 on timeslot P3"

Post by tot3nkopf »

What incident number is that? Give us the incidents from incvisu, not the explanation from incinfo.
is the incident related to your second post? Do you have traces from ISDN and IP when this occurs?
Kinne_DUP

Re: "Error P1 on message type P2 on timeslot P3"

Post by Kinne_DUP »

Nummer 3512
Bearbeitetes Objekt \Netzwerk::1\Teilnetz::2\Baugruppenträger::2\Leiterplatten::0
Ereignistyp Fehleralarmverarbeitung
Anzeigezeit 14.09.09 15:45:37
Mögliche Ursache Unbekannt
Bewertungsstufe unbestimmt
Empfangszeit 14.09.09 15:45:14
Anzeige-Id 35596
Kinne_DUP

Re: "Error P1 on message type P2 on timeslot P3"

Post by Kinne_DUP »

diagnose number is 4.403. I have no IP and ISDN traces, yet.