T1 Trunk State shows out of Service

jimbob

Post by jimbob »

Check the Synchronisation Priority on the PRA interface i.e. system, shelf, board, digital access. It should be set to something other than 255; or else it will sync to the CPU clock, not the carrier trunk clock.

Cheers,
James.
jimbob

Post by jimbob »

Also check that the PRA trunk is configured as point-to-point (at both ends).
niko

Post by niko »

jimbob wrote:Also check that the PRA trunk is configured as point-to-point (at both ends).
Thanks Jimbob.

Actually I set the synch priority to 200. I will try to find out where to set the point-to-point settings in the PCX...