Diagnostic Fault ID: 1307

Post Reply
drasko44
Member
Posts: 6
Joined: 20 Nov 2009 09:35

Diagnostic Fault ID: 1307

Post by drasko44 »

Hi to everyone !
On Alcatel 4400 I have lot of same alarms with information Diagnostic Fault ID 1307.
Diagnostic:
MCDU in distri tab entity P1, col P2, line P3 incorrect or missing missing.
P1 : Number of entity whose CDT has an incorrect or missing MCDU
P2: CDT column (night, day, call forwardingl, call forwarding2) with incorrect
or missing MCDU. The column is not significant if P3»3
P3 : Number of CDT line with the incorrect or missing MCDU if its value is
between 1 and 3. If it is superiorto 3, the night routing MCDU is
incorrect or missing.
OPE_BAD_ENTITY_CDT_CONTENT
Aterminal or a trunk calls an entity whose CDT or night routing MCDU is not correctly filled in. One of the MCDUs is incorrect or missing.
Indication of dialling of a wrong number on the caller's side or checking of the call.
Check the configuration of CDT or the entity of night routing. The night routing MCDU is compulsory.

What I must do to correct this fault
thx
User avatar
murraya
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 900
Joined: 16 Oct 2007 02:35

Post by murraya »

When a call fails to be answered or times out it will look at the respective "entity" to be routed.
Check the error and look at the entity in P1. Fill in correctly the "day", "night" routing fields to a valid number i.e the operator.
Best Regards
Murray

ACSE 10.0 corporate
ACSE 6.x IPT data
User avatar
Eliott
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 640
Joined: 10 Feb 2010 03:43

Post by Eliott »

See also TC0410: Risk of misfunctioning if the management of overflow directory number of entities/attendant groups is not performed ...
drasko44
Member
Posts: 6
Joined: 20 Nov 2009 09:35

Post by drasko44 »

Huh
txs for replies. i search everywhere but i can't find TC0410. if somebody have this documet please put link for download.
User avatar
Eliott
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 640
Joined: 10 Feb 2010 03:43

Post by Eliott »

See attachment...
You do not have the required permissions to view the files attached to this post.
drasko44
Member
Posts: 6
Joined: 20 Nov 2009 09:35

Post by drasko44 »

Thx Eliott but for some reason I can't opet this link.

"drasko44, you do not have permission to access this page. This could be due to one of several reasons:

1. Your user account may not have sufficient privileges to access this page. Are you trying to edit someone else's post, access administrative features or some other privileged system?
2. If you are trying to post, the administrator may have disabled your account, or it may be awaiting activation."
Can I give you my mail address to send me.
User avatar
Eliott
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 640
Joined: 10 Feb 2010 03:43

Post by Eliott »

Mmmy. I think you need more postings as described in the forum rules.

Raw-Text-Content:
1
TECHNICAL COMMUNICATION No. TC0410 Date : 15-01-2003
OmniPCX 4400 Nb of pages : 1
URGENT PERMANENT
SUBJECT : RISK OF MISFUNCTIONING IF THE MANAGEMENT OF OVERFLOW DIRECTORY
NUMBER OF ENTITIES/ATTENDANT GROUPS IS NOT PERFORMED
1. PROBLEM
Risk of misfunctioning if the management of overflow directory number of entities/attendant groups is
not performed.
Concerned releases
All.
2. CONSEQUENCE
Misfunctioning such as backtraces or unexplained CPU reboot.
Memory corruption on private/public incoming calls if the final destination is one of these directory
numbers.
These misfunctioning do not occur immediately.
The checkdb command is used to check the status of entity management: an incident is sent for each
entity or attendant groups if the overflow directory number is wrong or not correctly managed.
Examples of incidents
4351=Data inconsistency : appli INITREM table ENTITY cause invalid cdt info 0 -1 –1
Manage the overflow directory number.
ERROR 4351 : DATA INCONSISTENCY CDT cdt not initalized info1=1 info2=0 info3=-1
Wrong management of overflow directory number (attendant group call distribution) : the
directory number is wrong.
ERROR 4351 : DATA INCONSISTENCY CDT cdt not initalized info1=0 info2=1 info3=-1
Wrong management of overflow directory number (attendant call distribution) : the directory
number is wrong.
01/10/02 08:26:28 000001M|00/11/0/000|=3:1307=MCDU tab distri entite 1, col Day, lig 4
incorrect ou absent
3. SOLUTION
Manage the various overflow directory numbers until the checkdb et telephone application incidents
disappear.
Post Reply