Hi everyone,
Somebody would tell me if the OmniTouch 4135 can handle more of 4 phone calls simultaneous?
Indeed, i can't found this information and i need it
Thanks for your help
olook
Maximum Calls in Conference Phone 4135
-
corwin
if you register 4135 as sip extension in oxe
you are working with NOE emulation: call is limited to 3
if you register 4135 as sip device in oxe
well it should handle up to 5, but i doubt it s working
see com technical communication TC1252 4135 setup
3. LIMITATION
The OmniTouch 4135 IP does not support yet five lines conferences. It can establish a conference for three lines maximum.
you are working with NOE emulation: call is limited to 3
if you register 4135 as sip device in oxe
well it should handle up to 5, but i doubt it s working
see com technical communication TC1252 4135 setup
3. LIMITATION
The OmniTouch 4135 IP does not support yet five lines conferences. It can establish a conference for three lines maximum.
-
corwin
just for your information in the current 4135 version, calling meetme prefix fails
you canot register the access code
the new 4135 beta version (starting in september) solve such issue
even myteamwork may fails
currently when logged in myteamwork and specifying to cll 4135 sip number
the call is coming
i fail to input 1 to confirm the access to conference
so i perform a direct call from 4135 to myteamwork conf number
and this way access code + 1 to confirm entry to confierence, works
you canot register the access code
the new 4135 beta version (starting in september) solve such issue
even myteamwork may fails
currently when logged in myteamwork and specifying to cll 4135 sip number
the call is coming
i fail to input 1 to confirm the access to conference
so i perform a direct call from 4135 to myteamwork conf number
and this way access code + 1 to confirm entry to confierence, works
-
olook
Hi,
Corwin has the good answer. Thanks to you.
Fort tot3nkopf: DTMF is set in the good configuration, no problem about it. Are you still happy about this equipment?
But, i don't understand why i cannot use the common oxe fonctions as "*29". Cause it's a SIP equipment? I guess you can by-pass, but why don t you use on the 4135.
Regards,
olook
Corwin has the good answer. Thanks to you.
Fort tot3nkopf: DTMF is set in the good configuration, no problem about it. Are you still happy about this equipment?
But, i don't understand why i cannot use the common oxe fonctions as "*29". Cause it's a SIP equipment? I guess you can by-pass, but why don t you use on the 4135.
Regards,
olook