PCM2 DSP declared Out of Service

Post Reply
User avatar
Heimo
Member
Posts: 10
Joined: 21 May 2007 14:39

PCM2 DSP declared Out of Service

Post by Heimo »

OXE Crystal Hardware R7.1 f5.401.36.d
Problem with DSP of PCM2 board.

Its DSP are automatically declared Out of Service after first seizure attempt and is not possible to dial anymore. Only partial solution I've found is command "tcyc aux off" but auxiliary test are enabled after every CPU reset.

I've tryied:
Change PCM2 board
Erase and recreate board, trunk group and trunks
Reinstall CPU version

It seems to be a DB problem? First PCM2 board was working well for a while so I don't think it is a version problem.
User avatar
alex
Senior Member
Posts: 1498
Joined: 06 Jul 2004 07:27
Contact:

Re: PCM2 DSP declared Out of Service

Post by alex »

What "incvisu" shows after you reset this PCM2 and after 1st seizure attempt?
If it looks like a duck, swims like a duck, and quacks like a duck, then it probably is a duck.
User avatar
Heimo
Member
Posts: 10
Joined: 21 May 2007 14:39

Re: PCM2 DSP declared Out of Service

Post by Heimo »

It shows:
24/04/12 23:52:42 000001M|00/09/0/064|=2:2064=Out of service DSP
24/04/12 23:52:52 000001M|00/09/0/072|=2:2064=Out of service DSP

For all internal PCM2 DSP
Post Reply