How to recover a corrupted 6850

Post Reply
hamadaltaf

How to recover a corrupted 6850

Post by hamadaltaf »

Hi,

Is there a way to push a new image file to 6850 and force it to reload the new image.

For some reason the switch in my lab is gone down. When I try to connect through console, I get the following error in an infinite loop pattern.

===============================================================================
CPU: MPC8247 (HiP7 Rev 14, Mask 1.0 1K50M) at 400 MHz
Board: Alcaü

U-Boot (6.3.4.265.R01) (for OS6400, OS6850, and OS6855 platforms) (Dec 15 2008 - 21:31:42)

MPC8247 Reset Status: External Soft, External Hard

MPC8247 Clock Configuration
- Bus-to-Core Mult 4x, VCO Div 2, 60x Bus Freq 25-75 , Core Freq 100-300
- dfbrg 0, corecnf 0x1a, busdf 3, cpmdf 1, plldf 0, pllmf 3
- vco_out 400000000, scc_clk 100000000, brg_clk 100000000
- cpu_clk 400000000, cpm_clk 200000000, bus_clk 100000000
- pci_clk 66666666

CPU: MPC8247 (HiP7 Rev 14, Mask 1.0 1K50M) at 400 MHz
==================================================================================

I see a blinking amber in the OK LED indicator. Any idea on how to fix this switch?

Thanks,
Hamad
devnull

Re: How to recover a corrupted 6850

Post by devnull »

can you stop in miniboot? if not i guess it's ready for an RMA..

With you uboot a usb recovery is not possible :-/
hamadaltaf

Re: How to recover a corrupted 6850

Post by hamadaltaf »

No. I am not able to interrupt this message in any way. It just keeps flowing.

If it is a software issue, is there any possibility of resetting the device to factory defaults?
devnull

Re: How to recover a corrupted 6850

Post by devnull »

If you can't get it into miniboot/uboot (which you normaly do by interrupting with "s" when the message appears), i don't know a way to reset it.
Post Reply