SNMP configuration for PRTG Network monitor

Post Reply
Anirudhh-123

SNMP configuration for PRTG Network monitor

Post by Anirudhh-123 »

Hi,
Done following SNMP configuration on switch for PRTG Network monitor.In PRTG Network monitor bandwidth utilization shows properly,But when adding sensor for cpu load,it is showing blank(there is no data)

aaa authentication snmp local
aaa authentication default local
user snmpuser read-write all password snmpuser no auth
snmp security no security
snmp community map mode enable
snmp community map public user snmpuser on
snmp station ip address snmpuser v2 enable
snmp trap absorption enable
snmp trap to webview enable

Regards,
Anirudhh
cavagnaro

Re: SNMP configuration for PRTG Network monitor

Post by cavagnaro »

Maybe you need to load some MIB?

Enviado de meu E6633 usando Tapatalk
devnull

Re: SNMP configuration for PRTG Network monitor

Post by devnull »

PRTG is not restricted by your snmp setup so it is probably querying the wrong oid.
CPU should be
snmpwalk -v 2c -c public 192.168.10.1 1.3.6.1.4.1.6486.800.1.2.1.16.1.1.2.1.1.14
Post Reply

Return to “OmniSwitch 6850 / 6850E”