v24 metering output

Post Reply
selectt_DUP

v24 metering output

Post by selectt_DUP »

Having trouble getting metering infomation from system.

Have activated metering in applications, selected v24, selected relevant filters and used port 2 for the output.

Changed the v24 port to login to check if port was working ok. When i changed it back to none, no output available.
In older levels of software you could "kick start" the port using ttyconf, can this still be done ?
Again in oldere releases i had to reset system to get port to work.
luckyme2

Re: v24 metering output

Post by luckyme2 »

- What system OXO or OXE ?
- Software version of the system ?
- If OXE v24 through IP ? or usual interface ?
- What serial interface type did you define ?
selectt_DUP

Re: v24 metering output

Post by selectt_DUP »

Sorry, system is a OXE release 8,Via port V24 Port.

I actually reset the system and changed the port application to other application and it started to work.

Is there a way of reseting v24 port without reseting system ?
mysticalself_DUP

Re: v24 metering output

Post by mysticalself_DUP »

The command to re-initialize the V24 process - DHS3_init -R V24CONFIG
Post Reply

Return to “System”