mobile100 reflexes not initilizing

Everything about the PWT, IBS, RBS, DECT..
Post Reply
penny

mobile100 reflexes not initilizing

Post by penny »

i am using oxe R6.2-f3.301-10-ng-c6s2, ibs 4070io part code:3bn66102aabe020540 and using mobile 100 reflex set part code:
3bn67132abac030508. i was configured ibs in the system. when i try to ininilize the mobile 100 reflex, it was showing system1 subscption running...
is it problem with versions or am i using faulty dect handset. i tried with 3 similar handsets.
i attached ibs output from system.

(1)xa000000> dectview ibs


================= DECT RESOURCES BUSY STATE ===============

Resource Max busy free percent busy
-----------------------------------------------------
Link 276 0 276 0.00
LCEI 300 0 300 0.00
ADPCM 0 0 0
Buffer UA-> 135 0 135 0.00

================= IBS States =======================

0/00/12 neqt 648 RPN : 1 INSERV 6 channels DECT V 2G37.00 even IDENT NOR
MAL


(1)xa000000> dectinfo ibs
IBS general informations
------------------------

+------+-------------------+-------------+---------------------+
| Pari ! Hexadecimal value | Octal value | Handover parameters |
+------+-------------------+-------------+---------------------+
| 0 | 12.00.8F.0F | 11000436074 | Default |
+------+-------------------+-------------+---------------------+

Static System Info = 03.FF
Fixed Part Capabilities = 00.51.10 High Layer Attributes = C2.02
Prolonged preamble on IBS-NG is used
MAX IBS by area = 256
User avatar
frank
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 3404
Joined: 06 Jul 2004 00:18
Location: New York
Contact:

Post by frank »

Once your IBS are configured, up and running, you need to assign the handset to the network using the command dectinston d XXXX , XXXX being the directory number. Then turn on the handset, and when it ask you to register, say yes.. Do it one at the time.
Code Free Or Die
penny

Post by penny »

i configured gap+ and i tried with same command dectinston d XXXX. still same problem. i am not clear whether pari value is correct.
how to assign pari value in ibs? by default it is 00000000000. is dect handsets not initilising because of pari value?
User avatar
frank
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 3404
Joined: 06 Jul 2004 00:18
Location: New York
Contact:

Post by frank »

Oh.... Though you had this one.. Yeah.. You need a PARI value for that ..
Just put 100004xxxx0 , xxxx being random numbers
Code Free Or Die
vad
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 3856
Joined: 23 Sep 2004 06:47

Post by vad »

DECT system - you say DECT IBS type.
DECT system/IBS - you manage PARI value like 1000040...0 or 4 (10digits).
Shelf - manage PARI value=PARI IBS.