Hi
When i try to create an extension with 4019/4029 set type in oxe rel7.1 in UA 32 board , if the address is 255,255,255 then it's ok but whenever i put equipment address then i get an error like below:
"Incompatible hardware for alcatel 8&9 series TDM set".
Any solution/help please.
Thank you.
Incompatible hardware for alcatel 8&9 series TDM set
-
ybelal
No. You need inter-ACT connection - RT2, INTOF, INTIP. Was system where people use INTIP for signaling (without VoIP and PRA2 for calls). But in this case you cannot dial internal number - you need to dial prefix+number.
If you cannot use INTOF - f.e. if used SDH/MUX 2 mbits equipment - you need 3d generation sets - 4004/4010/4020/4035.
If you cannot use INTOF - f.e. if used SDH/MUX 2 mbits equipment - you need 3d generation sets - 4004/4010/4020/4035.