I have Appliance Server on OXE Release 9.1 patch 25b
i am working on Remote Crystal Shelf over IP with INTIP3 configured as INTIP3B. INTIP3B tries to download binaries from appliance server. Appliance server IP: 61.5.158.10 , mask: 255.255.255.240 , gateway: 61.5.158.1 moreover INTIP3B MAC is defined in "ethernet params". INTIP3B IP is 61.5.158.11 in same network and 10.1.1.61 in different network.
I am getting flag errors after intip3 login: hence cause intip3 to reboot, as mentioned below. I also tried with other INTIP3 board and getting same incidents cause INTIP3B to reboot
=== BIENVENUE TO INTIP 3 software in INTIP3 / INTIPB role ===
WARNING: root account has no password
Use 'passwd root' to enter a valid password
intip3 login: FlagError 1c in SStart
FlgErr Targ:$1c(F_PSAL_ERR) Host:$64e5 Stat:StateStart
F_STOP_REQ> CurCnt:0ms WaitCnt:x32
ANO_INT_CPL_DRIVER 64e5 1c 1
F_STOP_ACK> CurCnt:6 WaitCnt:32
F_CDIR_REQ> CurCnt:0ms WaitCnt:x14
F_CDIR_ACQ> CurCnt:0 WaitCnt:14
/mnt/flash/info/c1nv/CorDmpIR_0 wr in flash
F_CDSTR_REQ> CurCnt:0ms WaitCnt:xc8
F_CDSTR_ACQ> CurCnt:1d WaitCnt:c8
/mnt/flash/info/c1nv/CorDmpDBG_0.txt wr in flash
F_CDDMM_REQ> CurCnt:0ms WaitCnt:x1f4
F_CDDMM_ACQ> CurCnt:0 WaitCnt:1f4
/mnt/flash/info/c1nv/CorDmpDMM_0 First Stuck wr in flash
F_CDDMM2_REQ> CurCnt:0ms WaitCnt:x1f4
F_CDDMM2_ACQ> CurCnt:0 WaitCnt:1f4
/mnt/flash/info/c1nv/CorDmpDMM_0 Last Stuck wr in flash
F_CDEND_REQ> CurCnt:0ms WaitCnt:x1f4
TheEnd-> Cur_flg_req:ec HstFlg:ec TrgFlg:1c CurCnt:0 WaitCnt:1f4
can anyone tell me what could be the issue?
INTIP3 issue
Re: INTIP3 issue
=> PSAL_ERR
You have to connect the PowerSupplyALarm wire of your ACT.
http://alcatelunleashed.com/viewtopic.p ... 022#p61370
You have to connect the PowerSupplyALarm wire of your ACT.
http://alcatelunleashed.com/viewtopic.p ... 022#p61370
Re: INTIP3 issue
However, your log shows: FlgErr Targ:$1c(F_PSAL_ERR) Host:$64e5 Stat:StateStart
-
Xero
Re: INTIP3 issue
Dear Eliott,
thanks for your prompt response i have gone through the link you have given in your post, and we have now connected PSAL with -48V, it was previously connected with + 48 V...thanks alot