Sync problem with pabx via remote link T2

youfo007

Sync problem with pabx via remote link T2

Post by youfo007 »

hello,

I've posted on this forum a question about how I can configure a link between T2 4400 and Siemens HICOM alcatel 398.

Now, thanks to a number of tests and research on the net, I could solve this problem and finally the communication is established.

I noticed that the connection T2 remains in service during and after 15min almost falls out of service and is automatically restored after 5min.

I found that this is a problem with the synchronization.

A red alarm is triggered on the map INTOF "SYN".

My question is how I can solve this prob synch.

for your information my config on digital access alcatel side is that it is "SLAVE".

thank you
User avatar
alex
Senior Member
Posts: 1498
Joined: 06 Jul 2004 07:27
Contact:

Re: Sync problem with pabx via remote link T2

Post by alex »

Check "infocs" command.
Looks like your systems are not synchronized - they run on internal sources so after some time they completely out of sync.
If it looks like a duck, swims like a duck, and quacks like a duck, then it probably is a duck.
youfo007

Re: Sync problem with pabx via remote link T2

Post by youfo007 »

hi,

pieces joined in the editor control infocs

thanks
You do not have the required permissions to view the files attached to this post.
youfo007

Re: Sync problem with pabx via remote link T2

Post by youfo007 »

hi


Image infocs here at the time of synchronization loss
You do not have the required permissions to view the files attached to this post.
User avatar
alex
Senior Member
Posts: 1498
Joined: 06 Jul 2004 07:27
Contact:

Re: Sync problem with pabx via remote link T2

Post by alex »

  • Read System Documentation/System Services/PCX Synchronization chapter.
  • Check for the latest patch of OXE version
  • Check whether HICOM act a s a master of synchronziation
If it looks like a duck, swims like a duck, and quacks like a duck, then it probably is a duck.
youfo007

Re: Sync problem with pabx via remote link T2

Post by youfo007 »

hi,

indeed, this is what I do now, but there's a party in the documentation that I did not understand:

Read Documentation System / System Services / PCX Synchronization chapter.
Check for the latest patch release of OXE
Check Whether HICOM act asa master of synchronziation

how to check the latest patch

Siemens is in master

thanks.
User avatar
alex
Senior Member
Posts: 1498
Joined: 06 Jul 2004 07:27
Contact:

Re: Sync problem with pabx via remote link T2

Post by alex »

youfo007 wrote: how to check the latest patch
Which version do you have? A string printed out on login something like R10.0-j1.410-bla-bla-bla
If it looks like a duck, swims like a duck, and quacks like a duck, then it probably is a duck.
youfo007

Re: Sync problem with pabx via remote link T2

Post by youfo007 »

hi

release 6.1 whith CPU6
youfo007

Re: Sync problem with pabx via remote link T2

Post by youfo007 »

R6.1-f2.500-6-i-ma-c6s2
User avatar
alex
Senior Member
Posts: 1498
Joined: 06 Jul 2004 07:27
Contact:

Re: Sync problem with pabx via remote link T2

Post by alex »

You'd better check with the latest f2.502.33.a.
If it looks like a duck, swims like a duck, and quacks like a duck, then it probably is a duck.
Post Reply

Return to “Trunk Groups”