HI ALL,
I have 2 Cabinet (Shelf 2-0 GD Card and Shelf 3-0 MEX Card)
Under Shelf-2, it have PRA-T1 x 2 (2-6, 2-7). Is it possible to add T1 Trunk under MEX/ PowerMEX Cabinet in 3-6 or 3-7?
Thanks
Is it possible to add T1 Trunk under MEX/ PowerMEX
-
hunggundam
- Member
- Posts: 100
- Joined: 21 Jul 2011 05:04
Re: Is it possible to add T1 Trunk under MEX/ PowerMEX
Actis says yes 
Best Regards
Murray
ACSE 10.0 corporate
ACSE 6.x IPT data
Murray
ACSE 10.0 corporate
ACSE 6.x IPT data
Re: Is it possible to add T1 Trunk under MEX/ PowerMEX
i don't see where would be the problem if the related access will not be the highest priority of synch
Is it possible to add T1 Trunk under MEX/ PowerMEX
yes it is possible. but take in account that you cannot receive syncronisation in this case. also i think it is not possible to send syncronisation if configured as master.
regards...
regards...
-
hunggundam
- Member
- Posts: 100
- Joined: 21 Jul 2011 05:04
Re: Is it possible to add T1 Trunk under MEX/ PowerMEX
Thank you for all buddies
Real Case is requires to connect AudioCodes T1 Gateway by Q-SIG protocol. It is work under GD Cabinet, but it was not test under MEX Cabinet and without synchronization priority.
Anybody have reference case similar as this case? It is work synchronization = 255 to tie AudioCodes or other PBX?
Thanks
Real Case is requires to connect AudioCodes T1 Gateway by Q-SIG protocol. It is work under GD Cabinet, but it was not test under MEX Cabinet and without synchronization priority.
Anybody have reference case similar as this case? It is work synchronization = 255 to tie AudioCodes or other PBX?
Thanks