End of dialing timer

Post Reply
User avatar
sunder.J
Member
Posts: 38
Joined: 05 Feb 2010 07:40
Location: Chennai, India
Contact:

End of dialing timer

Post by sunder.J »

Hi,
I have a Qsig connectivity between OXE and Ericsson MD110 on PRI. I need the Timer value to reduce the end of dialing timer as there are multiple length of digits that are dialed from OXE to MD110 hence I couldn't manage the length in trunk group. The calling from OXE to MD110 is done through Direct speed dial .
Many thanks to help
haroun
Senior Member
Posts: 1464
Joined: 29 Mar 2010 11:09

Re: End of dialing timer

Post by haroun »

becarefull it's timer 18,
or professional trunkseize without overlap prefix and use dynamic key -send -
or the end of dialling equivalent in most of case is #
User avatar
sunder.J
Member
Posts: 38
Joined: 05 Feb 2010 07:40
Location: Chennai, India
Contact:

Re: End of dialing timer

Post by sunder.J »

Will timer 18 have impact in ISDN trunk . I tried to educate the customer on using # but he is not ok for it.
cavagnaro

Re: End of dialing timer

Post by cavagnaro »

Configure your discriminator with fixed lenghts, not 255. That will make the dial go out as soon as you reach the amount of numbers on each rule.
haroun
Senior Member
Posts: 1464
Joined: 29 Mar 2010 11:09

Re: End of dialing timer

Post by haroun »

You're using dir abreviated number please post a sample of that DAN
may be you add # to reall the called number( tg prefix seize+destination number +#) under DAN
User avatar
sunder.J
Member
Posts: 38
Joined: 05 Feb 2010 07:40
Location: Chennai, India
Contact:

Re: End of dialing timer

Post by sunder.J »

Yes, but I have variable length speed dial numbers DAN 52 & 53 have 5 digit length and DAN 00 has 2 digit for which I have used # at the end , Please find below the captures of sample DAN
Call Number : #2200#
Directory name : Enquiry
Directory First Name : --------------------
UTF-8 Directory Name : -------------------------------------------
UTF-8 Directory First Name : -------------------------------------------
Call Restrictions - Barring + False
Overfl.Dir.Spd Dl.No. Pref. : --------
Auto.Attendant Calling Right : 0
Call Type + Normal
Timed Forward.Dir.Spd.Dl.No. : --------
Range Number : 255
Can be Called/Dialed By Name + NO
Displayed Name : 00
External DISA Dir.No. : --------
--------------------------------------------------------------------------------------------
Direct Speed Dial No. Prefix : 00
Direct Speed Dial No. Prefix : 52

Call Number : #2252
Directory name : MD110
Directory First Name : --------------------
UTF-8 Directory Name : -------------------------------------------
UTF-8 Directory First Name : -------------------------------------------
Call Restrictions - Barring + False
Overfl.Dir.Spd Dl.No. Pref. : --------
Auto.Attendant Calling Right : 0
Call Type + Normal
Timed Forward.Dir.Spd.Dl.No. : --------
Range Number : 255
Can be Called/Dialed By Name + YES
Displayed Name : MD110
External DISA Dir.No. : --------
Phone book Name (Dial by name) : MD110
Phone book First Name : --------
----------------------------------------------------------------------------------------

Direct Speed Dial No. Prefix : 53

Call Number : #2253
Directory name : --------------------
Directory First Name : --------------------
UTF-8 Directory Name : -------------------------------------------
UTF-8 Directory First Name : -------------------------------------------
Call Restrictions - Barring + False
Overfl.Dir.Spd Dl.No. Pref. : --------
Auto.Attendant Calling Right : 0
Call Type + Normal
Timed Forward.Dir.Spd.Dl.No. : --------
Range Number : 255
Can be Called/Dialed By Name + NO
Displayed Name : #2253
External DISA Dir.No. : --------
------------------------------------------------------------------------------------------------------
User avatar
murraya
Alcatel Unleashed Certified Guru
Alcatel Unleashed Certified Guru
Posts: 900
Joined: 16 Oct 2007 02:35

Re: End of dialing timer

Post by murraya »

hi, when you say variable length it looks like digit lengths are the same based leading number so you could set up a discriminator with 52 and 53 as length 5 and 00 as length 2.
Best Regards
Murray

ACSE 10.0 corporate
ACSE 6.x IPT data
Post Reply

Return to “System”