Service must be same?

Post Reply
Eagleman

Service must be same?

Post by Eagleman »

Hello All,
It is mandatory that service ID must be same for service, EPIPE,VPLS?.
Thanks,
Eagleman
Stoffen
Member
Posts: 153
Joined: 23 May 2014 05:32
Location: Norway

Re: Service must be same?

Post by Stoffen »

Hi.
Service ID might differ, but the VCID used in spoke/mesh-sdp must be the same.

Its quite common to use VCID = service ID, but it doesnt have to be like that.
[flash=]
Christoffer

Network System Expert Norway
Nokia SRA #265
Alcatel-Lucent SRC 3RP Certified #552
Alcatel-Lucent SRC NRS-2 Certified #1104
Huawei HCNP Routing & Switching certified
Cisco CCNP Certified
LinkedIN
[/flash]
Eagleman

Re: Service must be same?

Post by Eagleman »

Thanks for the prompt answer sir...

But can the VCID be 100:100 against the B-end with 100:200 and still work?

KR
Stoffen
Member
Posts: 153
Joined: 23 May 2014 05:32
Location: Norway

Re: Service must be same?

Post by Stoffen »

hi.
no, that will not work.

the sdp id will differ but vc-id must match.

R1:
spoke-sdp 2:100

r2:
spoke-sdp 1:100

that will work, not the other way around.
[flash=]
Christoffer

Network System Expert Norway
Nokia SRA #265
Alcatel-Lucent SRC 3RP Certified #552
Alcatel-Lucent SRC NRS-2 Certified #1104
Huawei HCNP Routing & Switching certified
Cisco CCNP Certified
LinkedIN
[/flash]
Post Reply