Confused with licemses

seriosha

Confused with licemses

Post by seriosha »

HEre is a problem (OXE)
I enter config 1 - it says t
+-------------------------------------------------------------------+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|----|----|------------|-----------|--------------|-----------------|
| 1 | 0 | GD|---------- | REG NOT INIT | BAD PCMS CODE |
| 1 | 2 | UAI 16|---------- | REG NOT INIT | BAD PCMS CODE |
| 1 | 4 | SLI 16(Z)|---------- | REG NOT INIT | BAD PCMS CODE |
| 1 | 5 | SLI 16(Z)|---------- | REG NOT INIT | BAD PCMS CODE |
| 1 | 6 | PRA T2|---------- | REG NOT INIT | BAD PCMS CODE |
| 1 | 7 | PRA T2|---------- | REG NOT INIT | BAD PCMS CODE |
| 1 | 8 | CS|---------- | CALL SERVER | BAD PCMS CODE |
+-------------------------------------------------------------------+

what that means?


How Can I change the status of the board it - Operational State + Disabled -(it is in
I'm should to activate somehow?
Thank U!!!
cavagnaro

Post by cavagnaro »

Connect your config cable to the GD config port, once there write mgconfig and configure the GD to make it on the subnet of CS and configure CS Ip address so they can synchronize.

Shouldn't it be better to ask some certified engineer to help you? There are many things that can be misconfigured and make the system doesn't work as expected. Just as a comment

Regards
freedom

Post by freedom »

The board will become operational by itself as soon as the configuration is correct.
In the callserver you should assign the GD with the correct MAC-adress.
In the GD you should also do the correct management as cavagnaro wrote before.

As soon as both configurations are correct the rack will become operational, just as the rest of the boards.

I agree with cavagnaro that if you're not able to do the management yourself it's better to ask a certified engineer.

Good Luck.
cavagnaro

Post by cavagnaro »

It seems that you are installing a OXE from zero considering your posts. Please really try to find some certified that can help you, the OXE has many settings and configurations that must be handled very carefully if you want a good instalation and a happy customer.

Regards
seriosha

Post by seriosha »

I agree with you guys/ it's hard for beginners....

I was learning OXE for a week. I took a course of administration. I think that one week is is not enough…
Anyways, if someone wants to help me.. I will appreciate it.
I’ve wild experience installing SAMSUNG, PANASONC, LG,
Thanx!
seriosha

Post by seriosha »

+-------------------------------------------------------------------+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|----|----|------------|-----------|--------------|-----------------|
| 1 | 0 | GD|---------- | IN SERVICE | BAD PCMS CODE |
| 1 | 2 | UAI 16|---------- | IN SERVICE | BAD PCMS CODE |
| 1 | 4 | SLI 16(Z)|---------- | IN SERVICE | BAD PCMS CODE |
| 1 | 5 | SLI 16(Z)|---------- | IN SERVICE | BAD PCMS CODE |
| 1 | 6 | PRA T2|---------- | IN SERVICE | BAD PCMS CODE |
| 1 | 7 | PRA T2|---------- | IN SERVICE | BAD PCMS CODE |
| 1 | 8 | CS|---------- | CALL SERVER | BAD PCMS CODE |
+-------------------------------------------------------------------+

I put boards in service
but there still BAD PCMS CODE
Is this means that boards configured incorrectly?
freedom

Post by freedom »

The message 'BAD PCMS CODE' doesn't mean that the boards aren't correctly configured.
It seems to me that all boards are in service without problems.
cavagnaro

Post by cavagnaro »

seriosha wrote: I was learning OXE for a week. I took a course of administration. I think that one week is is not enough…
Well,... to handle all OXE functions will take a little more time than that. Your course was for that, administration, no installation. I'll still recommend to get some expert on site. Configuring PRI's is maybe going to be hard, not even mentioning categories (phone, connection, trunk, access)

Where are you located? Maybe someone here may help you.

Regards
seriosha

Post by seriosha »

I'm from Saint-Petersburg, Russia
TMC_DUP

Post by TMC_DUP »

Post Reply

Return to “GENERAL”