Hi all,
i use VMware to create database for customer system (crystal): user, trunk group
but when i restore mao-acc to crystal system. every thing still identified with WMware. it not match with actual hardware (hardware address,....)
Crystal 0 :
+-------------------------------------------------------------------+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|----|----|------------|-----------|--------------|-----------------|
| 0 | 6 | CPU6|---------- | REG NOT INIT | NO PCMS CODE |
+-------------------------------------------------------------------+
> Reference rack number: 2
Crystal 1 :
+-------------------------------------------------------------------+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|----|----|------------|-----------|--------------|-----------------|
| 1 | 0 | UA_FICTIF| | IN SERVICE | NO PCMS CODE |
+-------------------------------------------------------------------+
Crystal 2 :
+-------------------------------------------------------------------+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|----|----|------------|-----------|--------------|-----------------|
| 2 | 2 | NPRAE|---------- | REG NOT INIT | NO PCMS CODE |
| 2 | 3 | NDDI2|---------- | REG NOT INIT | NO PCMS CODE |
| 2 | 5 | eUA32|---------- | REG NOT INIT | NO PCMS CODE |
| 2 | 7 | eUA32|---------- | REG NOT INIT | NO PCMS CODE |
| 2 | 8 | INTIPA| INT-IP | REG NOT INIT | NO PCMS CODE |
| 2 | 9 | GPA2|---------- | REG NOT INIT | NO PCMS CODE |
+-------------------------------------------------------------------+
Crystal 19 :
+-------------------------------------------------------------------+
| Cr | cpl| cpl type | hw type | cpl state | coupler ID |
|----|----|------------|-----------|--------------|-----------------|
| 19 | 0 | FICTIF| | REG NOT INIT | NO PCMS CODE |
| 19 | 1 | INTIP3A| | IN SERVICE | NO PCMS CODE |
| 19 | 2 | INTIP3A| | OUT OF SERV | NO PCMS CODE |
+-------------------------------------------------------------------+
any one have experience on this case pls share me how to do this job.
thanks
Restore mao data from VMware to Actual crystal system
-
doublevand981
never done an install that way as normally I would use a lab system with at least the correct cpu config. I suggest that you delete all cards and shelves form your database ( will will need to make sure users are not assigned ports, trunks are not assigned to trunk groups and nothing assigned to the GPA) then load the database onto the real system, Stop the runtel and load the ops files again.
give it a go and you may be okay.
give it a go and you may be okay.
Best Regards
Murray
ACSE 10.0 corporate
ACSE 6.x IPT data
Murray
ACSE 10.0 corporate
ACSE 6.x IPT data